2007 GILLIG LOW FLOOR
8 recalls, 0 complaints - 21 TSBs
18V418000 Jun 20, 2018
EXTERIOR LIGHTING:TURN SIGNAL
Defect Description
Gillig LLC (Gillig) is recalling certain 2001-2018 Gillig Low Floor transit buses. The turn signals may flash slowly, reducing their visibility to other drivers. As such, these vehicles fail to comply with the requirements of Federal Motor Vehicle Safety Standard (FMVSS) number 108, "Lamps, Reflec... Read more
Consequence
The reduced visibility of the turn signals can increase the risk of a crash.
Remedy
Gillig will notify owners, and dealers will update the software that controls the turn flash rate, free of charge. The recall began on August 2, 2018. Owners may contact Gillig customer service at 1-510-264-5073 or 1-800-735-1500.
17V119000 Feb 24, 2017
EXTERIOR LIGHTING:TURN SIGNAL
Defect Description
Gillig LLC (Gillig) is recalling certain model year 1997-2017 Low Floor transit buses. The front turn signals installed on standard profile (non-BRT) buses may not be sufficiently visible to other drivers or pedestrians. As such, these vehicles fail to comply with the requirements of Federal Motor... Read more
Consequence
The reduced visibility of the turn signals may increase the risk of a crash.
Remedy
Gillig will notify owners, and dealers will install turn signals that have increased visibility. The recall began June 7, 2019. Owners may contact Gillig customer service at 1-510-264-5073 or 1-800-735-1500.
14V358000 Jun 23, 2014
ENGINE AND ENGINE COOLING:ENGINE
Defect Description
Gillig, LLC (Gillig) is recalling certain model year 2007-2014 Lowfloor transit buses manufactured September 26, 2007, through January 24, 2014. In the affected vehicles, the engine oil sampling hose may leak oil due to being routed too closely to hot engine exhaust components.
Consequence
If the sampling hose leaks oil in the presence of hot engine engine exhaust components, there is an increased risk of fire.
Remedy
Gillig will notify owners, and dealers will inspect the oil sampling hose. If the hose is routed too closely, the hose will be removed, replaced and rerouted to provide appropriate clearance of the hot components. The recall is expected to begin in early August 2014. Owners may contact Gillig cus... Read more
09V368000 Sep 28, 2009
INTERIOR LIGHTING
Defect Description
GILLIG CORPORATION IS RECALLING CERTAIN MODEL YEAR 2001 THROUGH 2009 TRANSIT BUSES MANUFACTURED BETWEEN JANUARY 2001 AND SEPTEMBER 2009 EQUIPPED WITH LUMINATOR HORIZON LED SIDE DESTINATION SIGNS. THE CONNECTOR BOARD CAN CORRODE DUE TO AN ACCUMULATION OF MOISTURE UNDER THE CONNECTOR.
Consequence
A SHORT COULD OCCUR, POSSIBLY CAUSING SMOKE AND FIRE.
Remedy
GILLIG WILL NOTIFY OWNERS AND LUMINATOR WILL REPAIR THE BUSES FREE OF CHARGE. THE SAFETY RECALL BEGAN ON SPETEMBER 29, 2009. OWNERS MAY CONTACT LUMINATOR AT 1-972-516-3033 OR GILLIG FIELD SERVICES AT 1-800-735-1500.
08V175000 Apr 16, 2008
SUSPENSION
Defect Description
GILLIG IS RECALLING 31 MY 2007 29 FOOT LOW FLOOR TRANSIT BUSES EQUIPPED WITH SAF- HOLLAND ADL SERIES REAR SUSPENSIONS. IN SOME INSTANCES THE TRANSVERSE BEAM WAS NOT PROPERLY WELDED WHICH COULD RESULT IN A FAILURE OF THE WELD.
Consequence
IF THE WELD FAILS, VEHICLE STABILITY WHILE CORNERING COULD BE AFFECTED RESULTING IN LOSS OF VEHICLE CONTROL, POSSIBLY RESULTING IN A CRASH. IN ADDITION, THE TRANSVERSE BEAM COULD DROP TO THE GROUND CAUSING SPARKS THAT COULD CAUSE A FIRE HAZARD.
Remedy
GILLIG IS WORKING WITH SAF HOLLAND TO HAVE A VISUAL INSPECTION OF THE ADL TRANSVERSE BEAM PERFORMED. IF A WELD DEFECT IS IDENTIFIED, SAF HOLLAND WILL PROVIDE A SERVICE REPLACEMENT KIT THAT CONTAINS A NEW TRANSVERSE BEAM, ALL NECESSARY INSTALLATION HARDWARE, BEAM REPLACEMENT AND INSTRUCTIONS FREE OF... Read more
08V008000 Jan 9, 2008
SERVICE BRAKES, AIR
Defect Description
ON CERTAIN TRANSIT BUSES EQUIPPED WITH GRAHAM-WHITE AIR DRYERS, THE AIR DRYER TIMER MODULES MAY ALLOW SUFFICIENT QUANTITIES OF MOISTURE TO ENTER AND AFFECT THE OPERATION OF THE VEHICLE AIR BRAKE SYSTEM.
Consequence
FAILURE OF THE AIR BRAKE SYSTEM DUE TO MOISTURE COULD RESULT IN A CRASH.
Remedy
GILLIG, IN CONJUNCTION WITH GRAHAM-WHITE, WILL REPLACE THE AIR DRYER TIMER MODULE ON THE AFFECTED VEHICLES. THE RECALL BEGAN ON JANUARY 29, 2008. OWNERS MAY CONTACT GILLIG AT 1-510-785-1500 OR GRAHAM-WHITE AT 540-387-5620.
07V265000 Jun 8, 2007
ENGINE AND ENGINE COOLING
Defect Description
ON CERTAIN TRANSIT BUSES BUILT WITH CUMMINS ISM C876 ENGINES, THE ELECTRONIC CONTROL MODULE FAILS TO RECOGNIZE INPUTS OF THE VEHICLE ELECTRONIC CONTROL UNIT OR FROM A DRIVER ACTUATED DASH SWITCH THEREBY INCREASING THE RISK OF UNINTENDED (OR UNEXPECTED) ELEVATED EXHAUST TEMPERATURES.
Consequence
WHILE THIS CONDITION DOES NOT INVOLVE A RISK OF FIRE IN THE VEHICLE ITSELF, IT COULD PRESENT A FIRE HAZARD IN A SITUATION WHERE THE VEHICLE'S EXHAUST IS IN CLOSE PROXIMITY TO MATERIALS OR SUBSTANCES THAT CAN MELT, BURN, OR EXPLODE.
Remedy
CUMMINS, IN CONJUNCTION WITH GILLIG, WILL CONDUCT THE REMEDY CAMPAIGN. THE RECALL BEGAN ON JULY 31, 2007. OWNERS CAN CONTACT CUMMINS AT 1-800-343-7357 OR GILLIG AT 1-510-785-1500.
07V259000 Jun 7, 2007
STEERING:HYDRAULIC POWER ASSIST:HOSE, PIPING, AND CONNECTIONS
Defect Description
ON CERTAIN TRANSIT BUSES, THE HYDRAULIC HOSE LOCATED IN THE ENGINE COMPARTMENT WAS MANUFACTURED INCORRECTLY WHICH COULD CAUSE A HYDRAULIC FLUID LEAK.
Consequence
HYDRAULIC FLUID LEAKAGE COULD LEAD TO A LOSS OF FLUID WHICH COULD AFFECT VEHICLE STEERING OR CREATE THE CONDITIONS FOR A POTENTIAL ENGINE COMPARTMENT FIRE.
Remedy
GILLIG WILL PROVIDE CORRECT HOSES TO THEIR CUSTOMERS FOR REPLACEMENT OR WILL REPLACE THE HOSES FOR THEM. THE RECALL BEGAN ON JUNE 27, 2007. OWNERS MAY CONTACT GILLIG AT 1-510-785-1500.
No complaints found for this vehicle.
Technical Service Bulletins, 2007 GILLIG LOW FLOOR
21 manufacturer communications from 14 unique bulletins. TSBs describe known problems and recommended fixes from the manufacturer.
Most Affected Components
| Component | Bulletins |
|---|---|
| 010000 STEERING | 4 |
| 350000 EQUIPMENT | 3 |
| 013000 STEERING:GEAR BOX (OTHER THAN RACK AND PINION) | 3 |
| 355200 EQUIPMENT:OTHER:OWNERS/SERVICE/OTHER MANUAL | 2 |
| 062300 ENGINE AND ENGINE COOLING:COOLING SYSTEM:HOSES/LINES/PIPING/FITTINGS | 2 |
| 162000 STRUCTURE:BODY | 1 |
| 140000 AIR BAGS | 1 |
| 110000 ELECTRICAL SYSTEM | 1 |
FS-2019-02
May 6, 2019
062300 ENGINE AND ENGINE COOLING:COOLING SYSTEM:HOSES/LINES/PIPING/FITTINGS
Because of a supply issue with the blue hose covering, Eaton is temporarily making FC-300 hose using black covering. FC-300 hose assemblies made between October 2018 to May 2019 will be affected by this change.
FS-2018-02
Jan 10, 2018
010000 STEERING
A procedure to properly adjust the draglink so the socket won't over articulate, causing increased wear.
FS-2018-01
Jan 5, 2018
013000 STEERING:GEAR BOX (OTHER THAN RACK AND PINION)
It was found that an earlier Bulletin spec'd bolts that could be too long due to variances in bolt shoulder length, so this bulletin was written to make sure bolt attachments were correct.
FS-2018-01
Jan 5, 2018
010000 STEERING
It was found that an earlier Bulletin spec'd bolts that could be too long due to variances in bolt shoulder length, so this bulletin was written to make sure bolt attachments were correct.
FS-2017-03
Jul 6, 2017
020000 SUSPENSION
This field service bulletin is informing vehicle owners and aftermarket part purchasers that Neway?, a SAF-HOLLAND? division, has identified some suspension installation and monitoring issues on the ADLSD-120 suspension used on 29' Gillig b
FS-2016-06
Dec 20, 2016
010000 STEERING
Gillig has received reports of partial cracking in the steering gear mounting plate in some Low Floor buses. We are now requesting that owners of all Low Floor buses from model year 1997 through June, 2015 inspect the steering gear mounting
FS-2016-06
Dec 20, 2016
356000 EQUIPMENT ADAPTIVE/MOBILITY
Gillig has received reports of partial cracking in the steering gear mounting plate in some Low Floor buses. We are now requesting that owners of all Low Floor buses from model year 1997 through June, 2015 inspect the steering gear mounting
FS-2016-06
Dec 20, 2016
350000 EQUIPMENT
Gillig has received reports of partial cracking in the steering gear mounting plate in some Low Floor buses. We are now requesting that owners of all Low Floor buses from model year 1997 through June, 2015 inspect the steering gear mounting
FS-2016-06
Dec 20, 2016
013000 STEERING:GEAR BOX (OTHER THAN RACK AND PINION)
Gillig has received reports of partial cracking in the steering gear mounting plate in some Low Floor buses. We are now requesting that owners of all Low Floor buses from model year 1997 through June, 2015 inspect the steering gear mounting
FS-2016-06
Dec 20, 2016
010000 STEERING
Gillig has received reports of partial cracking in the steering gear mounting plate in some Low Floor buses. We are now requesting that owners of all Low Floor buses from model year 1997 through June, 2015 inspect the steering gear mounting
FS-2016-06
Dec 20, 2016
013000 STEERING:GEAR BOX (OTHER THAN RACK AND PINION)
Gillig has received reports of partial cracking in the steering gear mounting plate in some Low Floor buses. We are now requesting that owners of all Low Floor buses from model year 1997 through June, 2015 inspect the steering gear mounting
FS-2016-05
Sep 14, 2016
350000 EQUIPMENT
THIS FIELD SERVICE BULLETIN PROVIDES NEW INFORMATION FROM BORG WARNER (DELCO) REVISING THE MAINTENANCE PROCEDURE FOR STARTER B+ CABLE MAINTENANCE AND TORQUE VALUES.
FS-2016-02
Apr 20, 2016
357100 EQUIPMENT:APPLIANCE:AIR CONDITIONER
THIS FIELD SERVICE BULLETIN APPLIES TO ALL NON-HYBRID LOW FLOOR BUSES WITH 480 VOLT HVAC SYSTEMS. IT ADVISES INSTALLATION OF A LOCKOUT MECHANISM FOR THE BATTERY DISCONNECT SYSTEM. DETAILS ARE PROVIDED ON HOW TO OBTAIN A LOCKOUT PADLOCK FROM
FS-2016-01
Mar 18, 2016
350000 EQUIPMENT
THIS FIELD SERVICE BULLETIN APPLIES TO ALL LOW FLOOR BUSES WITH SKF AIR DRYERS. IT WARNS AGAINST THE USE OF NON-SKF CARTRIDGES IN SKF AIR DRYERS AND RECOMMENDS ONLY USING GENUINE SKF CARTRIDGES.
FS-2015-02
May 20, 2015
355200 EQUIPMENT:OTHER:OWNERS/SERVICE/OTHER MANUAL
THIS FIELD SERVICE BULLETIN APPLIES TO ALL LOW FLOOR BUSES. IT ADVISES ON THE NECESSITY OF MAINTAINING PROPER RIDE HEIGHT AND PROVIDES CURRENT INSPECTION AND ADJUSTMENT PROCEDURES.
FS-2014-02
Apr 24, 2014
092200 FUEL SYSTEM, OTHER:DELIVERY:HOSES, LINES/PIPING, AND FITTINGS
THIS FIELD SERVICE BULLETIN APPLIES TO ALL LOW FLOOR BUSES WITH AEROQUIP FC-300 COOLANT HOSES. EATON AEROQUIP HAS RECENTLY DETERMINED THAT NEWER COOLANTS CONTAINING OAT (ORGANIC ACID TECHNOLOGY) ARE NOT COMPATIBLE WITH THEIR FC300 HOSE MATE
FS-2014-02
Apr 24, 2014
062300 ENGINE AND ENGINE COOLING:COOLING SYSTEM:HOSES/LINES/PIPING/FITTINGS
THIS FIELD SERVICE BULLETIN APPLIES TO ALL LOW FLOOR BUSES WITH AEROQUIP FC-300 COOLANT HOSES. EATON AEROQUIP HAS RECENTLY DETERMINED THAT NEWER COOLANTS CONTAINING OAT (ORGANIC ACID TECHNOLOGY) ARE NOT COMPATIBLE WITH THEIR FC300 HOSE MATE
FS-2014-01
Apr 23, 2014
110000 ELECTRICAL SYSTEM
THIS FIELD SERVICE BULLETIN APPLIES TO ALL LOW FLOOR BUSES WITH LUMINATOR OR TWIN VISION DESTINATION SIGNS. IT ALERTS OWNERS OF AN OPERATIONAL WARNING ISSUED BY THE SUPPLIER AGAINST UTILIZING THE USB PORT ON THEIR DESTINATION SIGN TO CHARGE
FS-2013-02
Jun 26, 2013
140000 AIR BAGS
THIS FIELD SERVICE BULLETIN APPLIES TO ALL LOW FLOOR BUSES. IT PROVIDES INSTRUCTIONS FOR ADJUSTING THE FRONT AIR BAGS AFTER AN ALIGNMENT OR FOR RIDE ADJUSTMENT NEEDS.
FS-2013-01
Mar 6, 2013
355200 EQUIPMENT:OTHER:OWNERS/SERVICE/OTHER MANUAL
THIS FIELD SERVICE BULLETIN PROVIDES INSTRUCTIONS FOR ORDERING WARRANTY PARTS, FILING WARRANTY CLAIMS AND RETURNING WARRANTY PARTS.
FS-2012-02
Jan 13, 2012
162000 STRUCTURE:BODY
GILLIG: GILLIG'S RECOMMENDATIONS FOR THE UNDERBODY MAINTENANCE CAN BE FOUND IN CHAPTER 11 OF YOUR SERVICE MANUAL. *JS
NHTSA Safety Investigations, GILLIG LOW FLOOR
Investigations opened by NHTSA into potential safety defects. These are separate from recalls and may or may not result in a recall.
PE03007
Opened: Feb 7, 2003 , Closed: Feb 24, 2003
POWER CABLE GROUNDING
IN LATE OCTOBER 2002, GILLIG CORPORATION RELEASED A FIELD SERVICE BULLETIN ADVISING OWNERS THAT A PROTRUDING BOLT ON THE AIR CONDITIONING UNIT (A/C) COULD MAKE CONTACT WITH AN UNINSULATED POWER CABLE END AND POSSIBLY CAUSE A FIRE.THE REMEDY WAS TO REMOVE THE EXCESS LENGTH FROM THE A/C BOLT.AS A RESU... Read more
GILLIG LOW FLOOR - All Years Overview
Complete safety history for the GILLIG LOW FLOOR across all model years (1997, 2026).
314
Total Recalls
8
Total Complaints
1
Investigations
0
Reported Crashes
1
Reported Fires
0
Reported Deaths
GILLIG LOW FLOOR - Year by Year
Compare recalls and complaints across model years. Click any year to see full details.
| Year | Recalls | Complaints | |
|---|---|---|---|
| 2026 | 2 | 1 | View |
| 2025 | 4 | 0 | View |
| 2024 | 9 | 0 | View |
| 2023 | 15 | 0 | View |
| 2022 | 11 | 0 | View |
| 2021 | 12 | 0 | View |
| 2020 | 14 | 0 | View |
| 2019 | 12 | 1 | View |
| 2018 | 13 | 0 | View |
| 2017 | 15 | 0 | View |
| 2016 | 20 | 1 | View |
| 2015 | 19 | 0 | View |
| 2014 | 23 | 2 | View |
| 2013 | 17 | 0 | View |
| 2012 | 11 | 0 | View |
| 2011 | 10 | 0 | View |
| 2010 | 9 | 0 | View |
| 2009 | 5 | 0 | View |
| 2008 | 5 | 1 | View |
| 2007 (current) | 8 | 0 | |
| 2006 | 5 | 0 | View |
| 2005 | 4 | 0 | View |
| 2004 | 8 | 0 | View |
| 2003 | 9 | 1 | View |
| 2002 | 8 | 0 | View |
| 2001 | 10 | 0 | View |
| 2000 | 10 | 1 | View |
| 1999 | 10 | 0 | View |
| 1998 | 10 | 0 | View |
| 1997 | 6 | 0 | View |