1997 GILLIG LOW FLOOR
6 recalls, 0 complaints - 20 TSBs
17V119000 Feb 24, 2017
EXTERIOR LIGHTING:TURN SIGNAL
Defect Description
Gillig LLC (Gillig) is recalling certain model year 1997-2017 Low Floor transit buses. The front turn signals installed on standard profile (non-BRT) buses may not be sufficiently visible to other drivers or pedestrians. As such, these vehicles fail to comply with the requirements of Federal Motor... Read more
Consequence
The reduced visibility of the turn signals may increase the risk of a crash.
Remedy
Gillig will notify owners, and dealers will install turn signals that have increased visibility. The recall began June 7, 2019. Owners may contact Gillig customer service at 1-510-264-5073 or 1-800-735-1500.
04V486000 Oct 7, 2004
ENGINE AND ENGINE COOLING:ENGINE:OTHER FUEL TYPES:TURBO/SUPERCHARGER
Defect Description
ON CERTAIN TRANSIT BUSES EQUIPPED WITH DETROIT DIESEL SERIES 40 ENGINES, THE TURBOCHARGER CAN FAIL ALLOWING LUBRICATING OIL TO SPILL ONTO THE ENGINE.
Consequence
THIS CAN RESULT IN A FIRE IN THE ENGINE COMPARTMENT.
Remedy
DEALERS WILL INSPECT AND REPLACE THE TURBOCHARGER TO PREVENT THE POSSIBILITY OF AN ENGINE COMPARTMENT FIRE. DETROIT DIESEL IS CONDUCTING OWNER NOTIFICATION AND REMEDY FOR THIS CAMPAIGN. GILLIG ISSUED A RENOTIFICATION LETTER TO OWNERS ON FEBRUARY 27, 2007. OWNERS SHOULD CONTACT DETROIT DETROIT DIE... Read more
03V392000 Oct 14, 2003
ELECTRICAL SYSTEM:WIRING:FRONT UNDERHOOD
Defect Description
INCORRECT ASSEMBLY OF ELECTRICAL CONNECTIONS AND SECUREMENT IN THE ENGINE COMPARTMENT COULD COME LOOSE.
Consequence
INCORRECT ASSEMBLY COULD CAUSE ELECTRICAL SHORTS, ARCING, AND FIRE.
Remedy
DEALERS WILL INSPECT ENGINE COMPARTMENT WIRING FOR CORRECT CABLE ASSEMBLY, FASTNER TORQUE, AND CORRECT WIRE PROTECTION. OWNER NOTIFICATION BEGAN OCTOBER 29, 2003. OWNERS WHO TAKE THEIR VEHICLES TO AN AUTHORIZED DEALER ON AN AGREED UPON SERVICE DATE AND DO NOT RECEIVE THE FREE REMEDY WITHIN A REAS... Read more
02V325000 Dec 6, 2002
ENGINE AND ENGINE COOLING
Defect Description
ON CERTAIN LOW FLOOR 29', 35' AND 40' BUSES, THE ENGINE COMPARTMENT INSULATION COULD FATIGUE AND SAG, POTENTIALLY TOUCHING THE TURBOCHARGER.
Consequence
THIS COULD POTENTIALLY LEAD TO A VEHICLE FIRE.
Remedy
GILLIG IS PROVIDING THE OWNERS WITH NEW INSULATION AND INSTALLATION PROCEDURES. THE NEW INSULATION IS TO BE INSTALLED ON THE INSIDE SIDE SURFACE OF THE ACCESS HATCH AND A MECHANICAL RETAINING STRIP TO SUPPORT THE ADJACENT INSULATION. THE RETAINING STRIP IS ATTACHED WITH NUTS AND BOLTS. OWNER NOT... Read more
02V189000 Jul 25, 2002
STEERING:GEAR BOX (OTHER THAN RACK AND PINION)
Defect Description
ON CERTAIN LOW FLOOR 29, 35, AND 40 FOOT BUSES, THE STEERING GEAR INPUT SHAFT BOLT INSTALLED WAS A 3/8" DIAMETER COARSE THREAD GRADE 8 FASTENER INSTEAD OF THE REQUIRED 7/16" DIAMETER FINE THREAD GRADE 8 FASTENER.
Consequence
IN THE EVENT OF A CRASH OR SOME OTHER EXTRAORDINARY SHOCK LOAD ON THE STEERING, A LOSS OF STEERING COULD OCCUR.
Remedy
DEALERS WILL REPLACE THE SUSPECT FASTENER WITH THE CORRECT FASTENER. OWNER NOTIFICATION BEGAN AUGUST 6, 2002. OWNERS WHO TAKE THEIR VEHICLES TO AN AUTHORIZED DEALER ON AN AGREED UPON SERVICE DATE AND DO NOT RECEIVE THE FREE REMEDY WITHIN A REASONABLE TIME SHOULD CONTACT GILLIG AT 1-510-785-1500... Read more
02V059004 Mar 21, 2002
STRUCTURE:BODY:DOOR
Defect Description
ON CERTAIN TRANSIT BUSES EQUIPPED WITH ADHESIVELY BONDED ALUMINUM BUS DOOR PANELS, DUE TO AN IMPERFECT BONDING OF THE DOOR PANEL SKIN TO THE PANEL FRAME, ENVIRONMENTAL MOISTURE MAY INFILTRATE REGIONS OF IMPERFECT BONDING AND CAUSE SEPARATION OF THE FRAME AND DOOR PANEL.
Consequence
UNDER THESE CONDITIONS, IF THE PANEL IS SEPARATING OR HAS SEPARATED, A PASSENGER COULD FALL FROM THE BUS ONTO THE ROADWAY, POSSIBLY RESULTING IN PERSONAL INJURY OR DEATH.
Remedy
VAPOR WILL NOTIFY CUSTOMERS TO HAVE THEIR BUSES INSPECTED AND WILL INSTALL MECHANICAL FASTENERS TO ATTACH THE SKINS TO THE FRAME ELEMENTS FREE OF CHARGE. OWNERS WHO DO NOT RECEIVE THE FREE REMEDY WITHIN A REASONABLE TIME SHOULD CONTACT VAPOR CORPORATION AT 847-967-8300 OR VAPOR AT 1510-785-1500.
No complaints found for this vehicle.
Technical Service Bulletins, 1997 GILLIG LOW FLOOR
20 manufacturer communications from 13 unique bulletins. TSBs describe known problems and recommended fixes from the manufacturer.
Most Affected Components
| Component | Bulletins |
|---|---|
| 010000 STEERING | 4 |
| 350000 EQUIPMENT | 3 |
| 013000 STEERING:GEAR BOX (OTHER THAN RACK AND PINION) | 3 |
| 355200 EQUIPMENT:OTHER:OWNERS/SERVICE/OTHER MANUAL | 2 |
| 062300 ENGINE AND ENGINE COOLING:COOLING SYSTEM:HOSES/LINES/PIPING/FITTINGS | 2 |
| 162000 STRUCTURE:BODY | 1 |
| 140000 AIR BAGS | 1 |
| 110000 ELECTRICAL SYSTEM | 1 |
FS-2019-02
May 6, 2019
062300 ENGINE AND ENGINE COOLING:COOLING SYSTEM:HOSES/LINES/PIPING/FITTINGS
Because of a supply issue with the blue hose covering, Eaton is temporarily making FC-300 hose using black covering. FC-300 hose assemblies made between October 2018 to May 2019 will be affected by this change.
FS-2018-02
Jan 10, 2018
010000 STEERING
A procedure to properly adjust the draglink so the socket won't over articulate, causing increased wear.
FS-2018-01
Jan 5, 2018
013000 STEERING:GEAR BOX (OTHER THAN RACK AND PINION)
It was found that an earlier Bulletin spec'd bolts that could be too long due to variances in bolt shoulder length, so this bulletin was written to make sure bolt attachments were correct.
FS-2018-01
Jan 5, 2018
010000 STEERING
It was found that an earlier Bulletin spec'd bolts that could be too long due to variances in bolt shoulder length, so this bulletin was written to make sure bolt attachments were correct.
FS-2016-06
Dec 20, 2016
010000 STEERING
Gillig has received reports of partial cracking in the steering gear mounting plate in some Low Floor buses. We are now requesting that owners of all Low Floor buses from model year 1997 through June, 2015 inspect the steering gear mounting
FS-2016-06
Dec 20, 2016
356000 EQUIPMENT ADAPTIVE/MOBILITY
Gillig has received reports of partial cracking in the steering gear mounting plate in some Low Floor buses. We are now requesting that owners of all Low Floor buses from model year 1997 through June, 2015 inspect the steering gear mounting
FS-2016-06
Dec 20, 2016
350000 EQUIPMENT
Gillig has received reports of partial cracking in the steering gear mounting plate in some Low Floor buses. We are now requesting that owners of all Low Floor buses from model year 1997 through June, 2015 inspect the steering gear mounting
FS-2016-06
Dec 20, 2016
013000 STEERING:GEAR BOX (OTHER THAN RACK AND PINION)
Gillig has received reports of partial cracking in the steering gear mounting plate in some Low Floor buses. We are now requesting that owners of all Low Floor buses from model year 1997 through June, 2015 inspect the steering gear mounting
FS-2016-06
Dec 20, 2016
010000 STEERING
Gillig has received reports of partial cracking in the steering gear mounting plate in some Low Floor buses. We are now requesting that owners of all Low Floor buses from model year 1997 through June, 2015 inspect the steering gear mounting
FS-2016-06
Dec 20, 2016
013000 STEERING:GEAR BOX (OTHER THAN RACK AND PINION)
Gillig has received reports of partial cracking in the steering gear mounting plate in some Low Floor buses. We are now requesting that owners of all Low Floor buses from model year 1997 through June, 2015 inspect the steering gear mounting
FS-2016-05
Sep 14, 2016
350000 EQUIPMENT
THIS FIELD SERVICE BULLETIN PROVIDES NEW INFORMATION FROM BORG WARNER (DELCO) REVISING THE MAINTENANCE PROCEDURE FOR STARTER B+ CABLE MAINTENANCE AND TORQUE VALUES.
FS-2016-02
Apr 20, 2016
357100 EQUIPMENT:APPLIANCE:AIR CONDITIONER
THIS FIELD SERVICE BULLETIN APPLIES TO ALL NON-HYBRID LOW FLOOR BUSES WITH 480 VOLT HVAC SYSTEMS. IT ADVISES INSTALLATION OF A LOCKOUT MECHANISM FOR THE BATTERY DISCONNECT SYSTEM. DETAILS ARE PROVIDED ON HOW TO OBTAIN A LOCKOUT PADLOCK FROM
FS-2016-01
Mar 18, 2016
350000 EQUIPMENT
THIS FIELD SERVICE BULLETIN APPLIES TO ALL LOW FLOOR BUSES WITH SKF AIR DRYERS. IT WARNS AGAINST THE USE OF NON-SKF CARTRIDGES IN SKF AIR DRYERS AND RECOMMENDS ONLY USING GENUINE SKF CARTRIDGES.
FS-2015-02
May 20, 2015
355200 EQUIPMENT:OTHER:OWNERS/SERVICE/OTHER MANUAL
THIS FIELD SERVICE BULLETIN APPLIES TO ALL LOW FLOOR BUSES. IT ADVISES ON THE NECESSITY OF MAINTAINING PROPER RIDE HEIGHT AND PROVIDES CURRENT INSPECTION AND ADJUSTMENT PROCEDURES.
FS-2014-02
Apr 24, 2014
092200 FUEL SYSTEM, OTHER:DELIVERY:HOSES, LINES/PIPING, AND FITTINGS
THIS FIELD SERVICE BULLETIN APPLIES TO ALL LOW FLOOR BUSES WITH AEROQUIP FC-300 COOLANT HOSES. EATON AEROQUIP HAS RECENTLY DETERMINED THAT NEWER COOLANTS CONTAINING OAT (ORGANIC ACID TECHNOLOGY) ARE NOT COMPATIBLE WITH THEIR FC300 HOSE MATE
FS-2014-02
Apr 24, 2014
062300 ENGINE AND ENGINE COOLING:COOLING SYSTEM:HOSES/LINES/PIPING/FITTINGS
THIS FIELD SERVICE BULLETIN APPLIES TO ALL LOW FLOOR BUSES WITH AEROQUIP FC-300 COOLANT HOSES. EATON AEROQUIP HAS RECENTLY DETERMINED THAT NEWER COOLANTS CONTAINING OAT (ORGANIC ACID TECHNOLOGY) ARE NOT COMPATIBLE WITH THEIR FC300 HOSE MATE
FS-2014-01
Apr 23, 2014
110000 ELECTRICAL SYSTEM
THIS FIELD SERVICE BULLETIN APPLIES TO ALL LOW FLOOR BUSES WITH LUMINATOR OR TWIN VISION DESTINATION SIGNS. IT ALERTS OWNERS OF AN OPERATIONAL WARNING ISSUED BY THE SUPPLIER AGAINST UTILIZING THE USB PORT ON THEIR DESTINATION SIGN TO CHARGE
FS-2013-02
Jun 26, 2013
140000 AIR BAGS
THIS FIELD SERVICE BULLETIN APPLIES TO ALL LOW FLOOR BUSES. IT PROVIDES INSTRUCTIONS FOR ADJUSTING THE FRONT AIR BAGS AFTER AN ALIGNMENT OR FOR RIDE ADJUSTMENT NEEDS.
FS-2013-01
Mar 6, 2013
355200 EQUIPMENT:OTHER:OWNERS/SERVICE/OTHER MANUAL
THIS FIELD SERVICE BULLETIN PROVIDES INSTRUCTIONS FOR ORDERING WARRANTY PARTS, FILING WARRANTY CLAIMS AND RETURNING WARRANTY PARTS.
FS-2012-02
Jan 13, 2012
162000 STRUCTURE:BODY
GILLIG: GILLIG'S RECOMMENDATIONS FOR THE UNDERBODY MAINTENANCE CAN BE FOUND IN CHAPTER 11 OF YOUR SERVICE MANUAL. *JS
NHTSA Safety Investigations, GILLIG LOW FLOOR
Investigations opened by NHTSA into potential safety defects. These are separate from recalls and may or may not result in a recall.
PE03007
Opened: Feb 7, 2003 , Closed: Feb 24, 2003
POWER CABLE GROUNDING
IN LATE OCTOBER 2002, GILLIG CORPORATION RELEASED A FIELD SERVICE BULLETIN ADVISING OWNERS THAT A PROTRUDING BOLT ON THE AIR CONDITIONING UNIT (A/C) COULD MAKE CONTACT WITH AN UNINSULATED POWER CABLE END AND POSSIBLY CAUSE A FIRE.THE REMEDY WAS TO REMOVE THE EXCESS LENGTH FROM THE A/C BOLT.AS A RESU... Read more
GILLIG LOW FLOOR - All Years Overview
Complete safety history for the GILLIG LOW FLOOR across all model years (1997, 2026).
314
Total Recalls
8
Total Complaints
1
Investigations
0
Reported Crashes
1
Reported Fires
0
Reported Deaths
GILLIG LOW FLOOR - Year by Year
Compare recalls and complaints across model years. Click any year to see full details.
| Year | Recalls | Complaints | |
|---|---|---|---|
| 2026 | 2 | 1 | View |
| 2025 | 4 | 0 | View |
| 2024 | 9 | 0 | View |
| 2023 | 15 | 0 | View |
| 2022 | 11 | 0 | View |
| 2021 | 12 | 0 | View |
| 2020 | 14 | 0 | View |
| 2019 | 12 | 1 | View |
| 2018 | 13 | 0 | View |
| 2017 | 15 | 0 | View |
| 2016 | 20 | 1 | View |
| 2015 | 19 | 0 | View |
| 2014 | 23 | 2 | View |
| 2013 | 17 | 0 | View |
| 2012 | 11 | 0 | View |
| 2011 | 10 | 0 | View |
| 2010 | 9 | 0 | View |
| 2009 | 5 | 0 | View |
| 2008 | 5 | 1 | View |
| 2007 | 8 | 0 | View |
| 2006 | 5 | 0 | View |
| 2005 | 4 | 0 | View |
| 2004 | 8 | 0 | View |
| 2003 | 9 | 1 | View |
| 2002 | 8 | 0 | View |
| 2001 | 10 | 0 | View |
| 2000 | 10 | 1 | View |
| 1999 | 10 | 0 | View |
| 1998 | 10 | 0 | View |
| 1997 (current) | 6 | 0 |