CITY OF NOCONA

Texas — Community Water System — PWSID: TX1690002

System Information

PWSIDTX1690002
System NameCITY OF NOCONA
System TypeCommunity Water System
Water SourceSurface Water
Activity StatusActive
Owner TypeLocal
EPA Region06
Serves SchoolNo
WholesalerNo
First ReportedMar 14, 1980
Last ReportedJan 6, 2026

Location & Contact

StateTexas
CityNOCONA
ZIP Code76255-2102
Address102 CLAY ST
OrganizationFENOGLIO, ROBERT, H
Phone940-825-3282

Population & Service

Population Served3,170
Service Connections1,572

Drinking Water Violations (13)

This water system has 13 violations recorded in the EPA SDWIS database.

Begin Date End Date Contaminant Category Health-Based Major Measured Federal MCL State MCL Status Return to Compliance Rule
Jul 2, 2024 Consumer Confidence Rule Other No No Resolved Sep 12, 2024 Consumer Confidence Rule
Jul 2, 2024 Consumer Confidence Rule Other No No Resolved Sep 12, 2024 Consumer Confidence Rule
Jan 1, 2006 Mar 31, 2006 TTHM MCL Yes No .094 MG/L 0.080 mg/L Resolved Mar 31, 2006 Stage 1 Disinfectants and Disinfection Byproducts Rule
Jan 1, 2006 Mar 31, 2006 TTHM MCL Yes No .094 MG/L 0.080 mg/L Resolved Mar 31, 2006 Stage 1 Disinfectants and Disinfection Byproducts Rule
Oct 1, 2005 Dec 31, 2005 TTHM MCL Yes No .152 MG/L 0.080 mg/L Resolved Dec 31, 2005 Stage 1 Disinfectants and Disinfection Byproducts Rule
Jul 1, 2005 Sep 30, 2005 TTHM MCL Yes No .214 MG/L 0.080 mg/L Resolved Sep 30, 2005 Stage 1 Disinfectants and Disinfection Byproducts Rule
Jul 1, 2005 Sep 30, 2005 TTHM MCL Yes No .214 MG/L 0.080 mg/L Resolved Sep 30, 2005 Stage 1 Disinfectants and Disinfection Byproducts Rule
Jul 1, 2005 Sep 30, 2005 TTHM MCL Yes No .214 MG/L 0.080 mg/L Resolved Sep 30, 2005 Stage 1 Disinfectants and Disinfection Byproducts Rule
Apr 1, 2005 Jun 30, 2005 TTHM MCL Yes No .3 MG/L 0.080 mg/L Resolved Jun 30, 2005 Stage 1 Disinfectants and Disinfection Byproducts Rule
Jul 1, 2004 Sep 30, 2004 TTHM MCL Yes No .202 MG/L 0.080 mg/L Resolved Sep 30, 2004 Stage 1 Disinfectants and Disinfection Byproducts Rule
Apr 1, 2004 Jun 30, 2004 TTHM MCL Yes No .111 MG/L 0.080 mg/L Resolved Jun 30, 2004 Stage 1 Disinfectants and Disinfection Byproducts Rule
Jun 1, 2003 Jun 30, 2003 Surface Water Treatment Rule MR No Yes Resolved Jun 30, 2003 Surface Water Treatment Rule
No No

About This Water System

Public water system data comes from the EPA Safe Drinking Water Information System (SDWIS). Systems with violations must notify customers. Contact your water utility for the latest annual water quality report.

Browse All Water Systems Water Systems in Texas