Kittson-Marshall Rural Water System
Minnesota — Community Water System — PWSID: MN1450004
System Information
| PWSID | MN1450004 |
| System Name | Kittson-Marshall Rural Water System |
| System Type | Community Water System |
| Water Source | Ground Water Purchased |
| Activity Status | Inactive |
| Owner Type | Local |
| EPA Region | 05 |
| Serves School | No |
| Wholesaler | No |
| First Reported | Jan 24, 1981 |
| Last Reported | Jun 6, 2025 |
Location & Contact
| State | Minnesota |
| City | Donaldson |
| ZIP Code | 56720 |
| Address | P.O. Box 210 |
| Organization | Kittson-Marshall Rural Water System |
| Phone | 2184662835 |
Population & Service
| Population Served | 952 |
| Service Connections | 261 |
Drinking Water Violations (35)
This water system has 35 violations recorded in the EPA SDWIS database.
| Begin Date | End Date | Contaminant | Category | Health-Based | Major | Measured | Federal MCL | State MCL | Status | Return to Compliance | Rule |
|---|---|---|---|---|---|---|---|---|---|---|---|
| Jul 1, 2022 | Sep 30, 2022 | TTHM | MCL | Yes | No | .082 MG/L | 0.080 mg/L | — | Archived | Sep 30, 2022 | Stage 2 Disinfectants and Disinfection Byproducts Rule |
| Jul 1, 2022 | Sep 30, 2022 | TTHM | MCL | Yes | No | .082 MG/L | 0.080 mg/L | — | Archived | Sep 30, 2022 | Stage 2 Disinfectants and Disinfection Byproducts Rule |
| Jul 1, 2022 | Sep 30, 2022 | TTHM | MCL | Yes | No | .082 MG/L | 0.080 mg/L | — | Archived | Sep 30, 2022 | Stage 2 Disinfectants and Disinfection Byproducts Rule |
| Jul 1, 2022 | Sep 30, 2022 | TTHM | MCL | Yes | No | .082 MG/L | 0.080 mg/L | — | Archived | Sep 30, 2022 | Stage 2 Disinfectants and Disinfection Byproducts Rule |
| Oct 1, 2013 | Dec 31, 2013 | Chlorine | MR | No | Yes | — | 4.0 mg/L | — | Resolved | Dec 31, 2013 | Stage 1 Disinfectants and Disinfection Byproducts Rule |
| Oct 1, 2013 | Dec 31, 2013 | Chlorine | MR | No | Yes | — | 4.0 mg/L | — | Resolved | Dec 31, 2013 | Stage 1 Disinfectants and Disinfection Byproducts Rule |
| Oct 1, 2013 | Dec 31, 2013 | Chlorine | MR | No | Yes | — | 4.0 mg/L | — | Resolved | Dec 31, 2013 | Stage 1 Disinfectants and Disinfection Byproducts Rule |
| Oct 1, 2013 | Dec 31, 2013 | Chlorine | MR | No | Yes | — | 4.0 mg/L | — | Resolved | Dec 31, 2013 | Stage 1 Disinfectants and Disinfection Byproducts Rule |
| Jan 1, 2007 | Mar 31, 2007 | Chlorine | MR | No | Yes | — | 4.0 mg/L | — | Resolved | Mar 31, 2007 | Stage 1 Disinfectants and Disinfection Byproducts Rule |
| Jan 1, 2007 | Mar 31, 2007 | Chlorine | MR | No | Yes | — | 4.0 mg/L | — | Resolved | Mar 31, 2007 | Stage 1 Disinfectants and Disinfection Byproducts Rule |
| Jan 1, 2007 | Mar 31, 2007 | Chlorine | MR | No | Yes | — | 4.0 mg/L | — | Resolved | Mar 31, 2007 | Stage 1 Disinfectants and Disinfection Byproducts Rule |
| Jan 1, 2007 | Mar 31, 2007 | Chlorine | MR | No | Yes | — | 4.0 mg/L | — | Resolved | Mar 31, 2007 | Stage 1 Disinfectants and Disinfection Byproducts Rule |
| Jan 1, 2007 | Mar 31, 2007 | Coliform (TCR) | MR | No | No | — | 5% of samples | — | Resolved | Mar 31, 2007 | Total Coliform Rule |
| Jan 1, 2007 | Mar 31, 2007 | Coliform (TCR) | MR | No | No | — | 5% of samples | — | Resolved | Mar 31, 2007 | Total Coliform Rule |
| Jan 1, 2007 | Mar 31, 2007 | Coliform (TCR) | MR | No | No | — | 5% of samples | — | Resolved | Mar 31, 2007 | Total Coliform Rule |
| Jan 1, 2007 | Mar 31, 2007 | Coliform (TCR) | MR | No | No | — | 5% of samples | — | Resolved | Mar 31, 2007 | Total Coliform Rule |
| Jan 1, 2007 | Mar 31, 2007 | Coliform (TCR) | MR | No | No | — | 5% of samples | — | Resolved | Mar 31, 2007 | Total Coliform Rule |
| Jan 1, 2007 | Mar 31, 2007 | Coliform (TCR) | MR | No | No | — | 5% of samples | — | Resolved | Mar 31, 2007 | Total Coliform Rule |
| Jul 1, 1999 | — | Lead and Copper Rule | MR | No | No | — | TT | — | Resolved | Jun 30, 2000 | Lead and Copper Rule |
| Jul 1, 1999 | — | Lead and Copper Rule | MR | No | No | — | TT | — | Resolved | Jun 30, 2000 | Lead and Copper Rule |
| Jul 1, 1999 | — | Lead and Copper Rule | MR | No | No | — | TT | — | Resolved | Jun 30, 2000 | Lead and Copper Rule |
| Jul 1, 1999 | — | Lead and Copper Rule | MR | No | No | — | TT | — | Resolved | Jun 30, 2000 | Lead and Copper Rule |
| Jul 1, 1999 | — | Lead and Copper Rule | MR | No | No | — | TT | — | Resolved | Jun 30, 2000 | Lead and Copper Rule |
| Jun 1, 1996 | Jun 30, 1996 | Coliform (TCR) | MR | No | No | — | 5% of samples | — | Archived | Jun 30, 1996 | Total Coliform Rule |
| Jun 1, 1996 | Jun 30, 1996 | Coliform (TCR) | MR | No | No | — | 5% of samples | — | Archived | Jun 30, 1996 | Total Coliform Rule |
| Jun 1, 1996 | Jun 30, 1996 | Coliform (TCR) | MR | No | No | — | 5% of samples | — | Archived | Jun 30, 1996 | Total Coliform Rule |
| — | — | — | No | No | — | — | — | — | — | — | |
| — | — | — | No | No | — | — | — | — | — | — | |
| — | — | — | No | No | — | — | — | — | — | — | |
| — | — | — | No | No | — | — | — | — | — | — | |
| — | — | — | No | No | — | — | — | — | — | — | |
| — | — | — | No | No | — | — | — | — | — | — | |
| — | — | — | No | No | — | — | — | — | — | — | |
| — | — | — | No | No | — | — | — | — | — | — | |
| — | — | — | No | No | — | — | — | — | — | — |
About This Water System
Public water system data comes from the EPA Safe Drinking Water Information System (SDWIS). Systems with violations must notify customers. Contact your water utility for the latest annual water quality report.