"SHELL PIPELINE CO., L.P."

hazardous_liquid Incident — — January 13, 2010

Incident Information

Incident DateJanuary 13, 2010
Operator"SHELL PIPELINE CO., L.P."
CommodityHVL OR OTHER FLAMMABLE OR TOXIC FLUID WHICH IS A GAS AT AMBI
Pipeline Typehazardous_liquid

Location

State
Coordinates30.17240, -90.78200

Cause

CauseNATURAL FORCE DAMAGE
SubcauseTEMPERATURE

Casualties

Fatalities0
Injuries0

Costs

Property Damage$0
Emergency Response$0
Other Costs$0

Location Map

Incident Narrative

"THE RELEASE WAS DUE TO ICE THAT FORMED IN A 1.5 INCH GLOBE VALVE. THE ICE FORMED DUE TO UNUSUALLY COLD AMBIENT TEMPERATURES. THE VALVE WAS LOCATED ON A DEHYDRATION UNIT AND WAS PART OF THE WATER DRAIN SYSTEM. WHEN THE VALVE WAS LAST CLOSED, THE PRESENCE OF THE ICE ALLOWED THE VALVE TO SEAL. DURING THE REGENERATION CYCLE OF THE DEHYDRATION UNIT, THE TEMPERATURE INCREASED AND MELTED THE ICE. WITH THE ICE MELTED, THERE WAS NO LONGER A SEAL AND PROPYLENE WAS RELEASED THROUGH THE VALVE. 3/13/2013 - UPDATED PER PHMSA REQUEST."