SUNOCO PIPELINE L.P.
hazardous_liquid Incident — — March 15, 2010
Incident Information
| Incident Date | March 15, 2010 |
| Operator | SUNOCO PIPELINE L.P. |
| Commodity | CRUDE OIL |
| Pipeline Type | hazardous_liquid |
Location
| State | |
| Coordinates | 32.07267, -98.46948 |
Cause
| Cause | EQUIPMENT FAILURE |
| Subcause | NON-THREADED CONNECTION FAILURE |
Casualties
| Fatalities | 0 |
| Injuries | 0 |
Costs
| Property Damage | $0 |
| Emergency Response | $755 |
| Other Costs | $0 |
Location Map
Incident Narrative
TANK 2017 FILL LINE WAS ISOLATED DUE TO TANK CLEANING OPERATIONS. THERE WAS NO THERMAL/PRESSURE RELIEF SYSTEM ON THE FILL LINE SEGMENT WHICH RESULTED IN THE GASKET FAILURE DUE TO THERMAL STRESS. A PRESSURE RELIEF SYSTEM WAS INSTALLED ON THE LINE SEGMENT AS A RESULT OF THIS INCIDENT. RE-SUBMITTED ON 3/28/2013 TO INCLUDE PART E5F PER PHMSA REQUEST.