ENTERPRISE PRODUCTS OPERATING LLC

hazardous_liquid Incident — — December 6, 2010

Incident Information

Incident DateDecember 6, 2010
OperatorENTERPRISE PRODUCTS OPERATING LLC
CommodityHVL OR OTHER FLAMMABLE OR TOXIC FLUID WHICH IS A GAS AT AMBI
Pipeline Typehazardous_liquid

Location

State
Coordinates32.77594, -102.95944

Cause

CauseEQUIPMENT FAILURE
SubcausePUMP OR PUMP-RELATED EQUIPMENT

Casualties

Fatalities0
Injuries0

Costs

Property Damage$1,000
Emergency Response$0
Other Costs$0

Location Map

Incident Narrative

AN ENTERPRISE EMPLOYEE DISCOVERED A RELEASE ON A CRACKED NIPPLE ATTACHED AT THE PUMP SUCTION HEADER. THE PUMP WAS ISOLATED AND PRODUCT BLOWDOWN. THE CRACKED NIPPLE WAS REMOVED AND REPLACED. A VIBRATION STUDY INDICATED THAT ADDITIONAL SUPPORT OR RELOCATION OF THE NIPPLE WAS NEEDED TO PREVENT FURTHER RECURRENCE. OTHER PUMPS WERE REVIEWED FOR SIMILAR OPERATIONAL ENVIRONMENT AND MODIFICATIONS WERE MADE WHERE NEEDED TO REDUCE WEIGHT AND LENGTH OF SMALL BORE CONNECTIONS.

About This Pipeline Incident

Pipeline incident data is reported to the Pipeline and Hazardous Materials Safety Administration (PHMSA). All significant incidents involving fatalities, injuries, or property damage over $50,000 must be reported.

Back to All Incidents More Incidents in