ONEOK NGL PIPELINE LP

hazardous_liquid Incident — — May 14, 2011

Incident Information

Incident DateMay 14, 2011
OperatorONEOK NGL PIPELINE LP
CommodityHVL OR OTHER FLAMMABLE OR TOXIC FLUID WHICH IS A GAS AT AMBI
Pipeline Typehazardous_liquid

Location

State
Coordinates41.63902, -88.12416

Cause

CauseCORROSION FAILURE
SubcauseEXTERNAL CORROSION

Casualties

Fatalities0
Injuries0

Costs

Property Damage$549,459
Emergency Response$15,000
Other Costs$0

Location Map

Incident Narrative

"THIRD PARTY REPORTED PRODUCT RUNNING OUT OF PIPELINE VENT PIPES ON ONEOK 106W PIPELINE AT 135TH ST CROSSING IN ROMEOVILLE, ILL. PIPELINE CONTROL CENTER SHUT DOWN PIPELINE AND DISPATCHED ONEOK PERSONNEL. PIPELINE WAS ISOLATED BY BLOCKVALVES AND PRODUCT WAS FLARED AT ONEOK LEMONT STATION. CARRIER PIPE AT ROAD CROSSING WAS REMOVED AND REPLACED WITH NEW PIPE. REPLACEMENT PIPE WAS HYDROSTATICALLY TESTED BEFORE LINE WAS RETURNED TO OPERATION. FAILED PIPE WAS SENT OUT FOR METALLURGICAL ANALYSIS (KIEFNER & ASSOC.) TO DETERMINE CAUSE OF FAILURE. LEAK WAS CAUSED BY EXTERNAL CORROSION OF THE PIPE BODY WITHIN A CASED ROAD CROSSING. AN ISOLATED CORROSION PIT WAS FOUND UNDERNEASTH A CASING SPACER. THE METAL LOSS HAD REACHED A DEPTH OF 93% WALL THICKNESS, AT WHICH POINT THE REMAINING LIGAMENT FAILED DUE TO INTERNAL PRESSURE AND A QUARTER-INCH TEAR FORMED. THE CASING SPACERS USED FOR THIS PARTICULAR CROSSING WERE COMPRISED OF BOLT-ON STEEL SLEEVES THAT WERE INSULATED AND CUSHIONED FROM THE COATED PIPE SURFACE WITH A RUBBER PAD. THE RUBBER PAD WAS OUT OF POSITION ON THE CASING SPACER THAT WAS OVER THE LEAK SUCH THAT PART OF THE STEEL SPACER WAS IN CONTACT WITH THE PIPE SURFACE."

About This Pipeline Incident

Pipeline incident data is reported to the Pipeline and Hazardous Materials Safety Administration (PHMSA). All significant incidents involving fatalities, injuries, or property damage over $50,000 must be reported.

Back to All Incidents More Incidents in