"SHELL PIPELINE CO., L.P."

hazardous_liquid Incident — — July 25, 2011

Incident Information

Incident DateJuly 25, 2011
Operator"SHELL PIPELINE CO., L.P."
CommodityREFINED AND/OR PETROLEUM PRODUCT (NON-HVL) WHICH IS A LIQUID
Pipeline Typehazardous_liquid

Location

State
Coordinates29.71820, -95.12780

Cause

CauseEQUIPMENT FAILURE
SubcauseTHREADED CONNECTION/COUPLING FAILURE

Casualties

Fatalities0
Injuries0

Costs

Property Damage$0
Emergency Response$7,550
Other Costs$0

Location Map

Incident Narrative

"PROVER DRAIN THREADED CONNECTION WAS FOUND LEAKING JET FUEL DURING OPERATION. ISOLATED PROVER FROM PIPELINE SYSTEM. DRAINED PROVER. REMOVED TWO (2"") INCH THREADED PIPE NIPPLE FROM THREAD-O-LET FITTING ON PROVER. INSPECTED BOTH NIPPLE AND THREAD-O-LET. CLEANED BOTH. FOUND THE NIPPLE INSTALLED WITH THREE THREADS IN THE FITTING. AFTER INSPECTION AND CLEANING, RE-INSTALLED NIPPLE INTO FITTING. THE NIPPLE IS SET DEEPER INTO THE FITTING MAKING A TIGHT SEAL. STAND UP TESTED AND RETURNED TO SERVICE. RECOVERED PRODUCT. 3/13/2013 - UPDATED E5F PER REQUEST FROM PHMSA."

About This Pipeline Incident

Pipeline incident data is reported to the Pipeline and Hazardous Materials Safety Administration (PHMSA). All significant incidents involving fatalities, injuries, or property damage over $50,000 must be reported.

Back to All Incidents More Incidents in