EXXONMOBIL PIPELINE CO

hazardous_liquid Incident —

Incident Information

Report Date
OperatorEXXONMOBIL PIPELINE CO
Commodity—
Pipeline Typehazardous_liquid

Location

State
Coordinates32.28594, -94.50062

Cause

CauseCORROSION FAILURE
Subcause—

Casualties

Fatalities0
Injuries0

Costs

Property Damage
Lost Commodity
Public/Private Damage
Emergency Response
Environmental Remediation
Other Costs

Location Map

Incident Narrative

THE LEAK WAS EXCAVATED AND IT WAS DETERMINED TO BE AN PIN HOLE INTERNAL CORROSION LEAK. A TEMPORARY CLAMP WAS INSTALLED. PIPE IS SCHEDULE TO BE EMPTIED AND REMOVED . LEAK OCCURED INSIDE THE TANK FIREWALL AND 0.48 OR 20 GALON RELEASE TO SOIL INSIDE THE FIREWALL. REMEDIATED IMMEDIATELY. PIPE WAS DRAIN OF ALL OIL AND REMOVED. PIPE IS ISOLATED FROM SYSTEM. AL WORK COMPLETE 3-18-11 SUPPLEMENTAL REPORT 7-31-13 SUPPLEMENTAL CREATED TO CORRECT NULL IN PART E 5 (F) PIPELINE FUCTION SECTION-ADDED TRUNKLINE AS REQUESTED BY PHMSA.