KINDER MORGAN CO2 CO. LP
hazardous_liquid Incident —
Incident Information
| Report Date | — |
| Operator | KINDER MORGAN CO2 CO. LP |
| Commodity | — |
| Pipeline Type | hazardous_liquid |
Location
| State | |
| Coordinates | 31.06576, -103.17361 |
Cause
| Cause | OTHER ACCIDENT CAUSE |
| Subcause | — |
Casualties
| Fatalities | 0 |
| Injuries | 0 |
Costs
| Property Damage | — |
| Lost Commodity | — |
| Public/Private Damage | — |
| Emergency Response | — |
| Environmental Remediation | — |
| Other Costs | — |
Location Map
Incident Narrative
ON 10/21/2010 AT 17:26 AT KM CO2 MCCAMEY STATION LOCATED IN UPTON COUNTY, A RELIEF VALVE SET AND CALIBRATED TO OPERATE AT 2160 PSI POPPED/VENTED TO ATMOSPHERE AT 2085 PSIG DUE TO A PRESSURE SURGE FROM THIRD PARTY PUMP FACILITY. THE RELIEF DURATION WAS FROM 17:26 UNTIL 19:16 AT 2030 PSI AVERAGE PRESSURE. THE RELIEF VALVE IS INSTALLED IN A LOCATION TO PROTECT KINDER MORGAN'S PIPELINE. HOWEVER, THE INITIAL SET POINT WAS SET TOO LOW FOR THE ESTABLISHED MOP OF THE LINE. THE SET POINT HAS BEEN RESET TO 105% OF THE MOP, 2330 PSIG.