KINDER MORGAN CO2 CO. LP

hazardous_liquid Incident — — November 29, 2010

Incident Information

Incident DateNovember 29, 2010
OperatorKINDER MORGAN CO2 CO. LP
CommodityCO2 (CARBON DIOXIDE)
Pipeline Typehazardous_liquid

Location

State
Coordinates33.38649, -100.01332

Cause

CauseEQUIPMENT FAILURE
SubcauseNON-THREADED CONNECTION FAILURE

Casualties

Fatalities0
Injuries0

Costs

Property Damage$204
Emergency Response$200
Other Costs$0

Location Map

Incident Narrative

THE SMALL LEAK WAS FOUND ON THE 5-VALVE MANIFOLD ATTACHED TO THE ELECTRONIC FLOW METER (EFM) ON THE METER RUN. A SMALL ICE BALL HAD FORMED AND THE LEAKING CO2 WAS CONDENSING WATER VAPOR FROM THE AIR CREATING A SMALL VISIBLE CLOUD AND THE LEAK COULD BE HEARD. A KATZ OIL-FIELD OPERATOR DROVE BY THE METER SITE AND SAW AND THEN HEARD THE LEAK. HE CALLED IN THE LEAK. THE 5-VALVE MANIFOLD ON THE EFM IS SECURED BY FOUR 7/16"" DIAMETER BOLTS THAT TIGHTEN THE CIRCULAR BODY OVER TWO CIRCULAR TEFLON GASKETS TO MAKE A SEAL ON THE MOUNTING BASE. THERE WERE NO TORQUE SPECIFICATIONS SUPPLIED BY THE MANUFACTURER FOR MOUNTING THE VALVE MANIFOLD. THE BOLTS WERE NOT TIGHTENED UNIFORMLY AND A PORTION OF THE TEFLON GASKETS WAS DAMAGED DURING INSTALLTION, CREATING A PATH FOR THE CO2 TO LEAK.