MAGELLAN AMMONIA PIPELINE, L.P.

hazardous_liquid Incident — — April 21, 2011

Incident Information

Incident DateApril 21, 2011
OperatorMAGELLAN AMMONIA PIPELINE, L.P.
CommodityHVL OR OTHER FLAMMABLE OR TOXIC FLUID WHICH IS A GAS AT AMBI
Pipeline Typehazardous_liquid

Location

State
Coordinates38.93903, -97.42801

Cause

CauseEQUIPMENT FAILURE
SubcauseMALFUNCTION OF CONTROL/RELIEF EQUIPMENT

Casualties

Fatalities0
Injuries0

Costs

Property Damage$20,000
Emergency Response$1,000
Other Costs$0

Location Map

Incident Narrative

WHILE DRIVING ALONG THE LINE, A MAGELLAN EMPLOYEE DISCOVERED AN AREA WHERE THE VEGETATION APPEARD TO BE DEAD. THE LINE WAS EXCAVATED AND A THREADED FITTING ON A STOPPLE WAS FOUND TO BE LEAKING. A TEMPORARY REPAIR WAS MADE BY WELDING A STEEL COLLAR OVER THE FITTING. A PERMANENT REPAIR WAS SUBSEQUENTLY MADE BY REMOVING THE STOPPLES AND INSTALLING A SEGMENT OF NEW PIPE WHICH WAS HYDROSTATICALLY TESTED WITHOUT FAILURE.

About This Pipeline Incident

Pipeline incident data is reported to the Pipeline and Hazardous Materials Safety Administration (PHMSA). All significant incidents involving fatalities, injuries, or property damage over $50,000 must be reported.

Back to All Incidents More Incidents in