ENTERPRISE PRODUCTS OPERATING LLC

hazardous_liquid Incident —

Incident Information

Report Date
OperatorENTERPRISE PRODUCTS OPERATING LLC
Commodity—
Pipeline Typehazardous_liquid

Location

State
Coordinates32.77698, -102.95071

Cause

CauseEQUIPMENT FAILURE
Subcause—

Casualties

Fatalities0
Injuries0

Costs

Property Damage
Lost Commodity
Public/Private Damage
Emergency Response
Environmental Remediation
Other Costs

Location Map

Incident Narrative

PUMP SEAL FAILURE ON PUMP #3. OPERATIONS ATTEMPTED TO ISOLATE THE UNIT TO STOP THE RELEASE. SUCTION AND DISCHARGE VALVES WOULD NOT SEAT COMPLETELY. LINES WERE TIED INTO THE SEAL SYSTEM TO ROUTE ANY LEAKING PRODUCT (Y-GRADE) TO THE FLARE. THIS WAS A SEAL FAILURE ON THE INBOARD MECHANICAL SEAL OF THE PUMP. TECHS NOT ABLE TO CLEAR PUMP TO 0% LEL OF PRODUCT DUE TO VALVES NOT COMPLETELY SEALING. LEFT 4 PRODUCT HOSES TO PUMP & HEADERS PIPED TO THE FLARE/BLOWDOWN SYSTEM TO PREVENT WEATHERING PRODUCT INTO ATMOSPHERE. INFORMATION WILL BE FILED WITH THE TEXAS RAILROAD COMMISSION UNDER REPORT# 668 3/19/2013 UPDATED PART E5.F - NEAL BURRELL

About This Pipeline Incident

Pipeline incident data is reported to the Pipeline and Hazardous Materials Safety Administration (PHMSA). All significant incidents involving fatalities, injuries, or property damage over $50,000 must be reported.

Back to All Incidents More Incidents in