ENTERPRISE PRODUCTS OPERATING LLC

hazardous_liquid Incident —

Incident Information

Report Date
OperatorENTERPRISE PRODUCTS OPERATING LLC
Commodity—
Pipeline Typehazardous_liquid

Location

State
Coordinates32.77597, -102.95923

Cause

CauseEQUIPMENT FAILURE
Subcause—

Casualties

Fatalities0
Injuries0

Costs

Property Damage
Lost Commodity
Public/Private Damage
Emergency Response
Environmental Remediation
Other Costs

Location Map

Incident Narrative

AN ENTERPRISE TECHNICIAN DISCOVERED A Y-GRADE RELEASE ON THE PUMP CASING. THE PUMP WAS ISOLATED AND PRODUCT WAS EVACUATED. THE NIPPLE WAS REMOVED AND REPLACED WITH A PLUG TO PREVENT FURTHER LEAKS. A VIBRATION STUDY INDICATED THAT ADDITIONAL SUPPORT OR RELOCATION OF THE NIPPLE WAS NEEDED TO PREVENT FURTHER RECURRENCE. OTHER PUMPS WERE REVIEWED FOR SIMILAR OPERATIONAL ENVIRONMENT AND MODIFICATIONS WERE MADE WHERE NEEDED TO REDUCE WEIGHT AND LENGTH OF SMALL BORE CONNECTIONS.