CHEVRON PIPE LINE CO

hazardous_liquid Incident — — June 14, 2011

Incident Information

Incident DateJune 14, 2011
OperatorCHEVRON PIPE LINE CO
CommodityHVL OR OTHER FLAMMABLE OR TOXIC FLUID WHICH IS A GAS AT AMBI
Pipeline Typehazardous_liquid

Location

State
Coordinates32.77757, -102.95078

Cause

CauseEQUIPMENT FAILURE
SubcauseMALFUNCTION OF CONTROL/RELIEF EQUIPMENT

Casualties

Fatalities0
Injuries0

Costs

Property Damage$40,903
Emergency Response$3,000
Other Costs$0

Location Map

Incident Narrative

CPL EMPLOYEES WERE PUTTING A STOPPLE IN PLACE TO MAKE REPAIRS TO VALVES. DURING THE REMOVING OF THE SEGMENT BOLT ON THE COMPLETION PLUG, THE SCREW CAME OUT, CAUSING THE LEAK. EMPLOYEES WERE ON SITE AT THE TIME OF THE LEAK. THE LEAK WAS ISOLATED WITH MAIN LINE BLOCK VALVES MP39 AND MP52. VOLUME WAS VENTED TO ATMOSPHERE AT THE HOBBS STATION AND NITROGEN DISPLACEMENT BACK INTO THE PIPELINE. THE LINE WAS DISPLACED WITH NITROGEN, AND THE STOPPLE FITTING WAS REMOVED.

About This Pipeline Incident

Pipeline incident data is reported to the Pipeline and Hazardous Materials Safety Administration (PHMSA). All significant incidents involving fatalities, injuries, or property damage over $50,000 must be reported.

Back to All Incidents More Incidents in