ENTERPRISE CRUDE PIPELINE LLC

hazardous_liquid Incident —

Incident Information

Report Date
OperatorENTERPRISE CRUDE PIPELINE LLC
Commodity—
Pipeline Typehazardous_liquid

Location

State
Coordinates28.94961, -95.43029

Cause

CauseINCORRECT OPERATION
Subcause—

Casualties

Fatalities0
Injuries0

Costs

Property Damage
Lost Commodity
Public/Private Damage
Emergency Response
Environmental Remediation
Other Costs

Location Map

Incident Narrative

IN REFERENCE TO PARTS A(6), F, AND I, THIS REPORT IS BEING MADE AS PART OF A COMPREHENSIVE REVIEW AND ANALYSIS OF PRIOR INCIDENTS OR NEAR MISSES INVOLVING FLASH FIRE OR IGNITION OF FLAMMABLE VAPORS, PURSUANT TO A COMPLIANCE ORDER ISSUED BY PHMSA (CPF NO. 4-2014-5017). THE PURPOSE OF THIS JOB WAS TO INSTALL A TEE IN A 24-INCH PIPELINE. A SECTION OF THE PIPE WAS REMOVED BY COLD CUTTING AND A MUD PLUG WAS INSTALLED TO ISOLATE THE LINE FROM ANY REMAINING VAPORS DURING WELDING ON THE TEE. THE LINE WAS OPEN ON BOTH SIDES OF THE MUD PLUG PRIOR TO ITS INSTALLATION. WHILE THE LINE WAS BEING CUT, ANOTHER CREW WAS INSTRUCTED TO INSTALL A BLIND FLANGE ON THE LINE, ENCLOSING THE PIPE BETWEEN THE MUD PLUG AND THE BLIND FLANGE. RESIDUAL HYDROCARBONS IN THE ENCLOSED PIPE BUILT PRESSURE, EVENTUALLY CAUSING A MIST TO OVERCOME THE MUD PLUG. THE MIST WAS IGNITED BY WELDING ON THE TEE, CAUSING A SHORT-DURATION FLASH FIRE.

About This Pipeline Incident

Pipeline incident data is reported to the Pipeline and Hazardous Materials Safety Administration (PHMSA). All significant incidents involving fatalities, injuries, or property damage over $50,000 must be reported.

Back to All Incidents More Incidents in