SHELL PIPELINE CO., L.P.

hazardous_liquid Incident —

Incident Information

Report Date
OperatorSHELL PIPELINE CO., L.P.
Commodity—
Pipeline Typehazardous_liquid

Location

State
Coordinates30.15683, -90.85372

Cause

CauseINCORRECT OPERATION
Subcause—

Casualties

Fatalities0
Injuries0

Costs

Property Damage
Lost Commodity
Public/Private Damage
Emergency Response
Environmental Remediation
Other Costs

Location Map

Incident Narrative

WHILE REFILLING A MANIFOLD AND TANK LINE, FOLLOWING A VALVE INSTALLATION, CRUDE OIL BURPED THROUGH THE WIPER AND MECHANICAL SEALS ONTO THE ROOF OF TK 512. RAIN THEN WASHED THE OIL OFF THE ROOF AND INTO THE TANK DIKE. CLEAN UP CREWS AND RECOVERED OIL. ALL OIL IS CONTAINED IN THE TANK DIKE. FIRE RESPONSE CREW IS ON STANDBY DUE TO THE THREAT OF CONTINUED THUNDERSTORMS IN AREA. THE SEALS WERE INSPECTED AND THE AFFECTED AREA WAS REPLACED. DETERMINED THAT THE PROCEDURE WAS NOT ADEQUATE FOR THE FILLING OF THE DRAINED MANIFOLD AND TANK LINE PRIOR TO TRANSFERRING CRUDE OIL FROM TANK TO TANK. PERSONNEL INVOLVED WERE QUALIFIED TO PERFORM THE TASKS OF REPLACING THE MANIFOLD VALVE AND FILLING THE EVACUATED PIPING. 3/13/2013 - UPDATED E5F PER PHMSA REQUEST. 7/3/13 - UPDATED PART D 7 DW, ECO