KOCH PIPELINE COMPANY, L.P.

hazardous_liquid Incident — — July 24, 2012

Incident Information

Incident DateJuly 24, 2012
OperatorKOCH PIPELINE COMPANY, L.P.
CommodityCRUDE OIL
Pipeline Typehazardous_liquid

Location

State
Coordinates46.81974, -95.14888

Cause

CauseEQUIPMENT FAILURE
SubcauseMALFUNCTION OF CONTROL/RELIEF EQUIPMENT

Casualties

Fatalities0
Injuries0

Costs

Property Damage$23,877
Emergency Response$0
Other Costs$0

Location Map

Incident Narrative

WHILE PERFORMING A STATION CHECK CRUDE OIL WAS OBSERVED ON THE GROUND BELOW THE PARK RAPIDS STATION CONTROL VALVE BY THE OPERATIONS TECHNICIAN. CRUDE OIL ESCAPED THROUGH THE SHAFT SEAL OF THE CONTROL VALVE, BUT STAYED WITHIN THE STATION GRAVEL DIKE. THE SEAL HAD BEEN REPLACED TWO WEEKS PRIOR TO THE RELEASE AND DURING THE PREVIOUS WEEK'S STATION CHECK THERE WAS NO SIGN OF A RELEASE. THE STATION WAS IMMEDIATELY SHUT DOWN AND CONTROL VALVE ISOLATED. THE SEAL WAS REPLACED WITH A FACTORY PRIMARY SEAL, A REDUNDANT PRIMARY SEAL AND A REDUNDANT SECONDARY SEAL. THE TWO ADDITIONAL SEALS DID PREVENT A SIMILAR OCCURRENCE UNTIL THE VALVE WAS REPLACED. KOCH PIPELINE HAS REPLACED THE PARK RAPIDS CONTROL VALVE WITH A FACTORY REFURBISHED CONTROL VALVE EQUIPPED WITH THE UPDATED LIVE LOAD STEM SEALS, REINSTALLED INTO THE PIPELINE THAT WE EXPECT TO BE A PERMANENT FIX.

About This Pipeline Incident

Pipeline incident data is reported to the Pipeline and Hazardous Materials Safety Administration (PHMSA). All significant incidents involving fatalities, injuries, or property damage over $50,000 must be reported.

Back to All Incidents More Incidents in