PLAINS PIPELINE, L.P.
hazardous_liquid Incident —
Incident Information
| Report Date | — |
| Operator | PLAINS PIPELINE, L.P. |
| Commodity | — |
| Pipeline Type | hazardous_liquid |
Location
| State | |
| Coordinates | 43.85167, -106.40833 |
Cause
| Cause | EQUIPMENT FAILURE |
| Subcause | — |
Casualties
| Fatalities | 0 |
| Injuries | 0 |
Costs
| Property Damage | — |
| Lost Commodity | — |
| Public/Private Damage | — |
| Emergency Response | — |
| Environmental Remediation | — |
| Other Costs | — |
Location Map
Incident Narrative
THE PUMP SEAL FAILURE WAS FROM A SPARE PUMP AND MOTOR ASSEMBLY THAT HAD BEEN INSTALLED THE PREVIOUS DAY. A NEW SEAL ASSEMBLY WAS INSTALLED IN THE SPARE UNIT PRIOR TO START UP. THE SEAL FAILED APPROXIMATELY 24 HOURS AFTER INSTALLATION. FOLLOWING THE FAILURE, THE SEAL WAS SENT TO THE SUPPLIER FOR EXAMINATION AND SHOWED EVIDENCE OF POSSIBLE MISALIGNMENT WHICH CAN BE CAUSED BY IMPROPER INSTALLATION SEQUENCE. IT WAS CONFIRMED THAT THE SEAL MANUFACTURER'S RECOMMENDED INSTALLATION SEQUENCE WAS FOLLOWED. THE ACTUAL CAUSE OF THE SEAL FAILURE IS INCONCLUSIVE.
About This Pipeline Incident