ENTERPRISE CRUDE PIPELINE LLC

hazardous_liquid Incident —

Incident Information

Report Date
OperatorENTERPRISE CRUDE PIPELINE LLC
Commodity—
Pipeline Typehazardous_liquid

Location

State
Coordinates32.08908, -102.13898

Cause

CauseEQUIPMENT FAILURE
Subcause—

Casualties

Fatalities0
Injuries0

Costs

Property Damage
Lost Commodity
Public/Private Damage
Emergency Response
Environmental Remediation
Other Costs

Location Map

Incident Narrative

DURING COMMISSIONING OPERATIONS AT 1 PM ON SEPT 27 AT COWDEN STATION, A 1.5"" GATE VALVE ON A STRAINER FAILED TO HOLD WHILE THE LINE WAS BEING FILLED. FLOW THROUGH THIS VALVE EMPTIED INTO THE STATION SUMP, AND AFTER FILLING THE SUMP OVERFLOWED. ABOUT 1.5 BARRELS OF CRUDE WERE SPILLED.

About This Pipeline Incident

Pipeline incident data is reported to the Pipeline and Hazardous Materials Safety Administration (PHMSA). All significant incidents involving fatalities, injuries, or property damage over $50,000 must be reported.

Back to All Incidents More Incidents in