ENTERPRISE CRUDE PIPELINE LLC
hazardous_liquid Incident — — April 23, 2014
Incident Information
| Incident Date | April 23, 2014 |
| Operator | ENTERPRISE CRUDE PIPELINE LLC |
| Commodity | CRUDE OIL |
| Pipeline Type | hazardous_liquid |
Location
| State | |
| Coordinates | 31.71890, -102.21213 |
Cause
| Cause | EQUIPMENT FAILURE |
| Subcause | DEFECTIVE OR LOOSE TUBING OR FITTING |
Casualties
| Fatalities | 0 |
| Injuries | 0 |
Costs
| Property Damage | $100 |
| Emergency Response | $2,000 |
| Other Costs | $0 |
Location Map
Incident Narrative
CONTROL CENTER RECOGNIZED A LINE BALANCE VARIATION AND CALCULATION AROUND 21:12 ON 4/23/2014. AFTER THE TECHNICIAN ARRIVED ON SITE AT 22:50 IT WAS CONFIRMED THAT THE DISCHARGE STAINLESS STEEL 3/8 INCH TUBING OF THE PD PUMP AT THE STATION HAD FAILED. THE STATION WAS ISOLATED FROM THE C15 LINE AND TUBING WAS REPLACED AND STATION PUT BACK INTO SERVICE 4/24/14 10:30. EXCESSIVE VIBRATION ON THIS 3/8 INCH TUBING RESULTED IN THE TUBING LEAK. PREVIOUS SUPPORT HAD BEEN EXCAVATED AROUND THE AREA DURING A REMEDIATION AND CLEAN-UP OF PREVIOUS SOIL CONTAMINATION. TUBING WAS REPLACED WITH STAINLESS STEEL BRAIDED HOSE TO ABSORB AND ELIMINATE DIRECT VIBRATION.