PHILLIPS 66 PIPELINE LLC
hazardous_liquid Incident — — August 1, 2014
Incident Information
| Incident Date | August 1, 2014 |
| Operator | PHILLIPS 66 PIPELINE LLC |
| Commodity | HVL OR OTHER FLAMMABLE OR TOXIC FLUID WHICH IS A GAS AT AMBI |
| Pipeline Type | hazardous_liquid |
Location
| State | |
| Coordinates | 36.47280, -102.26882 |
Cause
| Cause | EQUIPMENT FAILURE |
| Subcause | PUMP OR PUMP-RELATED EQUIPMENT |
Casualties
| Fatalities | 0 |
| Injuries | 0 |
Costs
| Property Damage | $5,000 |
| Emergency Response | $0 |
| Other Costs | $0 |
Location Map
Incident Narrative
"AT 17:50 ON AUGUST 1, 2014, CONTROLLER RECIEVED A HAZARDOUS ATMOSPHERE ALARM AT KERRICK STATION. THE STATION WAS SHUTDOWN AND BYPASSED AND THE AREA SUPERVISOR WAS NOTIFIED. TECHNICIAN ARRIVED AT KERRICK STATION AT 22:00 AND FOUND THE #2 UNIT INBOARD SEAL HAD FAILED. THE UNIT WAS ISOLATED AND BLED DOWN AND THE SEAL WAS REPLACED. THE PUMP WAS TESTED PRIOR TO RETURNING TO SERVICE."