MAGELLAN TERMINALS HOLDINGS, LP
hazardous_liquid Incident —
Incident Information
| Report Date | — |
| Operator | MAGELLAN TERMINALS HOLDINGS, LP |
| Commodity | — |
| Pipeline Type | hazardous_liquid |
Location
| State | |
| Coordinates | 35.94336, -96.75159 |
Cause
| Cause | CORROSION FAILURE |
| Subcause | — |
Casualties
| Fatalities | 0 |
| Injuries | 0 |
Costs
| Property Damage | — |
| Lost Commodity | — |
| Public/Private Damage | — |
| Emergency Response | — |
| Environmental Remediation | — |
| Other Costs | — |
Location Map
Incident Narrative
A LEAK OCCURRED ON THE PIPELINEDUE TO EXTERNAL CORROSION PITTING. THIS LINE WAS FOUND TO BE UNCOATED, HOWEVER CP READINGS SHOWED TO BE WELL ABOVE THE REQUIREMENTS. THE APPLIED CP DATE OF 1991 WAS BASED ON THE EARLIEST READINGS PROVIDED BY THE PREVIOUS OWNER OF THE RECTIFIER SERVICING THIS LINE. THIS LINE HAS BEEN REMOVED FROM SERVICE. A COURTESY NOTIFICATION WAS MADE TO THE NRC AS IT WAS UNKNOWN IF THE $50,000 CRITERIA WOULD BE MET. HOWEVER THIS RELEASE DID NOT MEET THE NOTIFICATION REQUIREMENTS. AN ATTEMPT TO SUBMIT THIS REPORT WAS MADE ON 5/17/13, HOWEVER, PHMSA'S WEBSITE WAS DOWN FOR THE WEEKEND DUE TO MAINTENANCE. THE INCIDENT INVESTIGATION CONCLUDED THAT THE CP WAS ADEQUATE ON THE LINE BUT WAS INCONCLUSIVE TO THE EXACT MODE OF FAILURE. IT IS UNKNOWN IF ADEQUATE CP WAS APPLIED DURING THE PREVIOUS OWNERSHIP AND MAY HAVE POTENTIALLY CONTRIBUTED TO THE CORROSION OF THE LINE. AS LOCAL PROJECTS ARE COMPLETED THE PIPING AND COATING CONDITIONS ARE EVALUATED AND IDENTIFIED ISSUES ARE ADDRESSED PER MAGELLAN'S 7.01-ADM-001 PIPELINE DEFECT EVALUATION AND REPAIR PROCEDURE.
About This Pipeline Incident
Pipeline incident data is reported to the Pipeline and Hazardous Materials Safety Administration (PHMSA). All significant incidents involving fatalities, injuries, or property damage over $50,000 must be reported.