MAGELLAN PIPELINE COMPANY, LP

hazardous_liquid Incident —

Incident Information

Report Date
OperatorMAGELLAN PIPELINE COMPANY, LP
Commodity—
Pipeline Typehazardous_liquid

Location

State
Coordinates37.80249, -96.91695

Cause

CauseEQUIPMENT FAILURE
Subcause—

Casualties

Fatalities0
Injuries0

Costs

Property Damage
Lost Commodity
Public/Private Damage
Emergency Response
Environmental Remediation
Other Costs

Location Map

Incident Narrative

THE INCIDENT OCCURRED WHILE AN OPERATOR WAS FILLING THE PROVER AT THE OSAGE METER STATION. THE DRAIN VALVE ON THE PROVER ( 4"" GENERAL TWIN SEAL) INDICATED THAT IT WAS IN THE CLOSED POSITION. WHEN FILLING THE PROVER, THE OPERATOR NOTICED THE SUMP LEVEL RAPIDLY INCREASING. THE OPERATOR INITIALLY REACTED BY CLOSING THE INCOMING VALVE AND ATTEMPTING TO START THE SUMP PUMP. HOWEVER, THE SUMP PUMP WAS UNABLE TO PRIME, PREVENTING ANY PRODUCT FROM BEING PUMPED OUT OF THE SUMP. THE SUMP EVENTUALLY OVERFILLED AND RELEASED APPROXIMATELY ONE BBL. THE OPERATOR THAN CLOSED THE AIR BLEEDER VALVE ON THE PROVER WHICH CREATED A VACUUM AND THUS PREVENTED ANY ADDITIONAL PRODUCT FROM DRAINING TO THE SUMP FROM THE PROVER. THE FAULTY VALVE WAS REPLACED WITH A NEW ONE. THE IMPACTED SOIL WAS REMEDIATED IN ACCORDANCE WIOTH COMPANY AND STATE STANDARDS.

About This Pipeline Incident

Pipeline incident data is reported to the Pipeline and Hazardous Materials Safety Administration (PHMSA). All significant incidents involving fatalities, injuries, or property damage over $50,000 must be reported.

Back to All Incidents More Incidents in