ENTERPRISE PRODUCTS OPERATING LLC

hazardous_liquid Incident — — December 30, 2014

Incident Information

Incident DateDecember 30, 2014
OperatorENTERPRISE PRODUCTS OPERATING LLC
CommodityHVL OR OTHER FLAMMABLE OR TOXIC FLUID WHICH IS A GAS AT AMBI
Pipeline Typehazardous_liquid

Location

State
Coordinates27.79952, -97.56450

Cause

CauseEQUIPMENT FAILURE
SubcauseNON-THREADED CONNECTION FAILURE

Casualties

Fatalities0
Injuries0

Costs

Property Damage$2,800
Emergency Response$1,000
Other Costs$0

Location Map

Incident Narrative

"ON 12/30/2014, MAINTENANCE PERSONNEL WERE PREPARING TO REPLACE A VALVE USING A STOPPLE AND A BLOCK VALVE. WHILE THE WORK WAS BEING PERFORMED, THE STOPPLE SEALING ELEMENT HAD DEVELOPED A SMALL LEAK. DURING THE PROCESS OF RETRACTING THE STOPPLE SEALING ELEMENT FOR REPLACEMENT, THE INSULATION FLANGE GASKET ON THE VALVE BEING REPLACED FAILED BEFORE THE SECOND SEALING ELEMENT WAS INSERTED. THE AFFECTED PIPE SEGMENT WAS ISOLATED AND BLOWN DOWN. THE VALVE INITIALLY BEING REPLACED WAS REMOVED AND REPLACED WITH A NEW VALVE AND NEW INSULATION GASKET. THE INSULATION GASKET WAS NEAR ITS LIFE EXPECTANCY. GASKET AGE COMBINED WITH THE MAINTENANCE WORK RESULTED IN ITS FAILURE."