CHEVRON PIPE LINE CO

hazardous_liquid Incident — — November 14, 2013

Incident Information

Incident DateNovember 14, 2013
OperatorCHEVRON PIPE LINE CO
CommodityHVL OR OTHER FLAMMABLE OR TOXIC FLUID WHICH IS A GAS AT AMBI
Pipeline Typehazardous_liquid

Location

State
Coordinates32.10804, -96.94382

Cause

CauseEXCAVATION DAMAGE
SubcauseEXCAVATION DAMAGE BY OPERATOR'S CONTRACTOR (SECOND PARTY)

Casualties

Fatalities0
Injuries0

Costs

Property Damage$1,500,000
Emergency Response$2,000,000
Other Costs$0

Location Map

Incident Narrative

AT 0933 CDT ON 11-14-13, THE CPL CONTROL CENTER WAS NOTIFIED OF A LINE STRIKE AND SUBSEQUENT RELEASE/FIRE ON THE 10' WEST TEXAS LPG LINE NEAR MILFORD, TX. A CPL CONTRACT CREW WAS DRILLING VERTICALLY TO INSTALL A POWER POLE AS PART OF A PROJECT TO INSTALL A CATHODIC PROTECTION DEEP GROUND BED, WHEN THEY STRUCK THE 10"" LPG LINE. THE LINE WAS SHUT IN UPSTREAM OF THE INCIDENT SITE AND PRESSURE WAS PULLED OFF USING THE DOWNSTREAM PUMPS, PRIOR TO BLOCKING THE DOWNSTREAM BLOCK VALVE. CPL MAINTENANCE CREWS EVACUATED THE DAMAGED 10' LINE AND THE ADJACENT 14' LPG MAINLINE TO REPLACE DAMAGED PIPE AND COMPONENTS. THE 10' LINE WAS RESTARTED ON 11-21-13 AND THE 14' MAINLINE WAS RESTARTED ON 11-23-13.

About This Pipeline Incident

Pipeline incident data is reported to the Pipeline and Hazardous Materials Safety Administration (PHMSA). All significant incidents involving fatalities, injuries, or property damage over $50,000 must be reported.

Back to All Incidents More Incidents in