"PLAINS PIPELINE, L.P."

hazardous_liquid Incident — — April 17, 2015

Incident Information

Incident DateApril 17, 2015
Operator"PLAINS PIPELINE, L.P."
CommodityCRUDE OIL
Pipeline Typehazardous_liquid

Location

State
Coordinates35.01975, -119.06454

Cause

CauseEQUIPMENT FAILURE
SubcauseTHREADED CONNECTION/COUPLING FAILURE

Casualties

Fatalities0
Injuries0

Costs

Property Damage$20
Emergency Response$5,000
Other Costs$0

Location Map

Incident Narrative

"APPROXIMATELY 0.95 BBLS OF CRUDE OIL WERE RELEASED FROM A 1-INCH PIPE NIPPLE, POSITIONED ON THE HIGH PRESSURE SIDE OF A MANIFOLD. PLAINS SCADA SYSTEM HELPED THE CONTROLLER IDENTIFY THAT THERE WAS A PROBLEM WITH A BACK PRESSURE CONTROL VALVE SO THE SYSTEM WAS SHUT DOWN AND A FIELD OPERATOR WAS DISPATCHED. UPON ARRIVAL, THE OPERATOR DISCOVERED THE SMALL LEAK. A 1-INCH NIPPLE FAILED AS A RESULT OF THE PRESSURE CONTROL VALVE NOT OPENING AND DIVERTING THE FLOW OF OIL. THIS THEN CAUSED THE RELIEF VALVE TO LIFT AND RESEAT CAUSING VIBRATION. THE DEFECTIVE NIPPLE WAS REMOVED AND PLUGGED AT THE 1-INCH TEST BRANCH CONNECTION. TO CORRECT THE VIBRATION ISSUE, PLAINS HAS CHANGED OUT THE POTENTIOMETER ON THE CONTROL VALVE AND ELIMINATED THE 1-INCH TEST MANIFOLD. PLAINS IS INSPECTING OTHER SIMILAR STATIONS IN THIS AREA FOR SIMILAR SETUPS AND WILL CORRECT THE PIPING AND CONTROL VALVE SETTINGS TO ELIMINATE ANY POTENTIAL VIBRATION."