COLONIAL PIPELINE CO

hazardous_liquid Incident —

Incident Information

Report Date
OperatorCOLONIAL PIPELINE CO
Commodity—
Pipeline Typehazardous_liquid

Location

State
Coordinates30.90931, -90.87143

Cause

CauseEQUIPMENT FAILURE
Subcause—

Casualties

Fatalities0
Injuries0

Costs

Property Damage
Lost Commodity
Public/Private Damage
Emergency Response
Environmental Remediation
Other Costs

Location Map

Incident Narrative

ON 5 FEBRUARY AT 0730, DURING A YARD CHECK, TECHNICIANS NOTED A PRODUCT SHEEN ON STANDING WATER IN THE LINE 2 AREA OF THE YARD. AN IMMEDIATE INVESTIGATION FOUND PRODUCT IN THE ACCESS WELLS IN THE VICINITY OF THE UNIT 3 CHECK VALVE. PRODUCT WAS REMOVED FROM THE ACCESS WELLS AND FROM THE STANDING WATER WITH APPROXIMATELY 40 GALLONS RECOVERED. THE CLEANUP WAS COMPLETED BY 0900 ON 2/5/14. MONITORING WAS CONDUCTED OVER THE NEXT 9 HOURS WITH NO NEW PRODUCT RELEASE OBSERVED. AT 0700 ON FEBRUARY 6TH A CREW ARRIVED AT THE STATION TO REMOVE THE WATER AND EXCAVATE AND INSPECT THE CHECK VALVES FOR UNITS 3 AND 4. A FLANGE ON THE INBOARD SPRING CANISTER FOR THE UNIT 3 CHECK VALVE WAS FOUND TO BE WEEPING. THE STATION WAS ISOLATED, DEPRESSURIZED, AND PERMANENT REPAIRS WERE MADE WITH COMPLETION TIME OF APPROXIMATELY 1100. NO OTHER LEAK SOURCES WERE FOUND. THE SPILL WAS REPORTED TO LOUISIANA DEQ ON 2/6/14 AT 7:54AM (REPORT #JI53 12539). SINCE THE EVENT DID NOT MEET NRC NOTIFICATION CRITERIA THE NRC WAS NOT NOTIFIED.

About This Pipeline Incident

Pipeline incident data is reported to the Pipeline and Hazardous Materials Safety Administration (PHMSA). All significant incidents involving fatalities, injuries, or property damage over $50,000 must be reported.

Back to All Incidents More Incidents in