SUNOCO PIPELINE L.P.

hazardous_liquid Incident — — June 14, 2015

Incident Information

Incident DateJune 14, 2015
OperatorSUNOCO PIPELINE L.P.
CommodityHVL OR OTHER FLAMMABLE OR TOXIC FLUID WHICH IS A GAS AT AMBI
Pipeline Typehazardous_liquid

Location

State
Coordinates41.62247, -83.48496

Cause

CauseEQUIPMENT FAILURE
SubcauseDEFECTIVE OR LOOSE TUBING OR FITTING

Casualties

Fatalities0
Injuries0

Costs

Property Damage$20
Emergency Response$2,500
Other Costs$0

Location Map

Incident Narrative

"AT 22:09 ON 6/14/2015, A FACILITY LOCKOUT ALARM CAME IN VIA SCADA FOR THE TOLEDO PUMP STATION (TOL5). THE TOL 5 PUMP WAS SHUT DOWN AND THE TOL5 PUMP STATION WAS ISOLATED FROM THE PIPELINE. THE CONTROLLER RESPONDED TO THE ALARM AND MONITORED FOR FURTHER INFORMATION. THE CONTROLLER NOTIFIED THE FIELD SUPERVISOR AND TECHNICIAN TO INVESTIGATE THE LOCKOUT CONDITIONS. UPON ARRIVAL AT TOL5, THE TECHNICIAN OBSERVED A VAPOR RELEASE AT THE AREA NEAR THE TOP OF THE PUMP. EMERGENCY RESPONSE WAS INITIATED. ETHANE/VAPORS WERE SAFELY CLEARED AND A TRANSITION TO MAINTENANCE/REPAIR STATUS WAS MADE ON 6/15/2015. IT WAS LATER CONFIRMED THAT A SWAGELOCK FITTING WAS THE SOURCE OF THE LEAK. THE FAILED FITTING WAS PART OF THE SEAL PRESSURE/COOLING MEDIUM SYSTEM. IT WAS DETERMINED THAT THE FITTING LEAKED BECAUSE IT WAS OVER-TIGHTENED WHEN INSTALLED."