ENTERPRISE CRUDE PIPELINE LLC

hazardous_liquid Incident —

Incident Information

Report Date
OperatorENTERPRISE CRUDE PIPELINE LLC
Commodity—
Pipeline Typehazardous_liquid

Location

State
Coordinates31.71890, -102.21213

Cause

CauseEQUIPMENT FAILURE
Subcause—

Casualties

Fatalities0
Injuries0

Costs

Property Damage
Lost Commodity
Public/Private Damage
Emergency Response
Environmental Remediation
Other Costs

Location Map

Incident Narrative

CONTROL CENTER RECOGNIZED A LINE BALANCE VARIATION AND CALCULATION AROUND 21:12 ON 4/23/2014. AFTER THE TECHNICIAN ARRIVED ON SITE AT 22:50 IT WAS CONFIRMED THAT THE DISCHARGE STAINLESS STEEL 3/8 INCH TUBING OF THE PD PUMP AT THE STATION HAD FAILED. THE STATION WAS ISOLATED FROM THE C15 LINE AND TUBING WAS REPLACED AND STATION PUT BACK INTO SERVICE 4/24/14 10:30. EXCESSIVE VIBRATION ON THIS 3/8 INCH TUBING RESULTED IN THE TUBING LEAK. PREVIOUS SUPPORT HAD BEEN EXCAVATED AROUND THE AREA DURING A REMEDIATION AND CLEAN-UP OF PREVIOUS SOIL CONTAMINATION. TUBING WAS REPLACED WITH STAINLESS STEEL BRAIDED HOSE TO ABSORB AND ELIMINATE DIRECT VIBRATION.