ENERGY TRANSFER COMPANY

hazardous_liquid Incident — — November 25, 2015

Incident Information

Incident DateNovember 25, 2015
OperatorENERGY TRANSFER COMPANY
CommodityCRUDE OIL
Pipeline Typehazardous_liquid

Location

State
Coordinates28.34480, -98.12120

Cause

CauseEQUIPMENT FAILURE
SubcauseOTHER EQUIPMENT FAILURE

Casualties

Fatalities0
Injuries0

Costs

Property Damage$1,500
Emergency Response$0
Other Costs$0

Location Map

Incident Narrative

"ON NOV. 25 AT APPROXIMATELY 2300 HRS., AFTER OPERATIONS COMPLETED ROUTINE BI-ANNUAL ESD TESTING, THE STATION WAS BEING BROUGHT BACK INTO SERVICE. A COMPANY I &E TECH NOTICED OIL COMING FROM THE SIDE OF THE CONTROL VALVE ON THE PRIMARY METER RUN. THE METER WAS IMMEDIATELY SHUT IN AND THE ALTERNATE METER WAS BROUGHT ON LINE AT APPROXIMATELY 2305 HRS. INVESTIGATION FOUND COVER OF THE PACKING SEAL LEAKING ON THE CONTROL VALVE. THE PRIMARY CONTROL VALVE HAD THE PACKING SEAL REPAIRED AND BROUGHT BACK ON LINE AND IN SERVICE AT 1300 HRS. ON DEC 2ND"