PHILLIPS 66 PIPELINE LLC

hazardous_liquid Incident —

Incident Information

Report Date
OperatorPHILLIPS 66 PIPELINE LLC
Commodity—
Pipeline Typehazardous_liquid

Location

State
Coordinates37.97665, -122.32213

Cause

CauseEQUIPMENT FAILURE
Subcause—

Casualties

Fatalities0
Injuries0

Costs

Property Damage
Lost Commodity
Public/Private Damage
Emergency Response
Environmental Remediation
Other Costs

Location Map

Incident Narrative

12:55 A REPORT OF GASOLINE ORDOR AT VALVE BOX #6 BY FIELD PERSONNEL. 15:15 FIELD REOPRTED THAT A VAC TRUCK WAS IN ROUTE. FOUND ABOUT 4'' OF PRODUCT IN THE 6X6 VALVE BOX. 19:20 VAULT CLEAN OUT ... LINE RESTARTED TO INSPECT THE PIPING IN THE VAULT. A SMALL LEAK WAS DISCOVERD AT THE BOTTOM OF THE MAINLINE BLOCK VALVE CAVITY RELIEF VALVE. RELIEF VALVE REPLACED, LINE RESTARTED TO REINSPECT THE VALVE. ALL OK. 19:30 STAND UP PRESSURE TEST NP01. 20:30 PRESSURE TEST ENDED, GIVEN OK TO RETURN LINE TO NORMAL OPERATION. 21:35 LINE UP AND RUNING.

About This Pipeline Incident

Pipeline incident data is reported to the Pipeline and Hazardous Materials Safety Administration (PHMSA). All significant incidents involving fatalities, injuries, or property damage over $50,000 must be reported.

Back to All Incidents More Incidents in