ENTERPRISE PRODUCTS OPERATING LLC

hazardous_liquid Incident —

Incident Information

Report Date
OperatorENTERPRISE PRODUCTS OPERATING LLC
Commodity—
Pipeline Typehazardous_liquid

Location

State
Coordinates30.19156, -95.35386

Cause

CauseEQUIPMENT FAILURE
Subcause—

Casualties

Fatalities0
Injuries0

Costs

Property Damage
Lost Commodity
Public/Private Damage
Emergency Response
Environmental Remediation
Other Costs

Location Map

Incident Narrative

DURING ROUTINE VALVE MAINTENANCE, CONROE STATION OPERATIONS PERSONNEL DISCOVERED A SMALL LEAK ON THE BONNET FLANGE THAT WAS ONLY DETECTABLE VIA LEL TESTING. AFTER IT WAS DETERMINED THAT THE ONLY WAY TO REPAIR THE VALVE WAS TO PERFORM A DOUBLE STOPPLE BYPASS TO BLOW DOWN THE VALVE BODY, IT WAS DEEMED REPORTABLE DUE TO GREATER THAN $50,000 IN MAINTENANCE COSTS. THE VALVE WAS REPAIRED AND PUT BACK IN TO SERVICE 11/3/2014 AT 21:00.

About This Pipeline Incident

Pipeline incident data is reported to the Pipeline and Hazardous Materials Safety Administration (PHMSA). All significant incidents involving fatalities, injuries, or property damage over $50,000 must be reported.