CENTRAL FLORIDA PIPELINE CORP

hazardous_liquid Incident — — November 16, 2014

Incident Information

Incident DateNovember 16, 2014
OperatorCENTRAL FLORIDA PIPELINE CORP
CommodityREFINED AND/OR PETROLEUM PRODUCT (NON-HVL) WHICH IS A LIQUID
Pipeline Typehazardous_liquid

Location

State
Coordinates28.42270, -81.37047

Cause

CauseINCORRECT OPERATION
SubcauseEQUIPMENT NOT INSTALLED PROPERLY

Casualties

Fatalities0
Injuries0

Costs

Property Damage$1,000
Emergency Response$0
Other Costs$0

Location Map

Incident Narrative

AN EMPLOYEE PERFORMING A FACILITY WALK AROUND NOTICED A SMALL FLAME COMING FROM A PRESSURE SENSING TUBING LINE. THE FLAME WAS EXTINGUISHED BY THE EMPLOYEE. AN INVESTIGATION OF THE INCIDENT REVEALED THE TUBING HAD NOT BEEN PROPERLY SECURED TO THE SUPPORT AFTER A PREVIOUS TUBING REPAIR. THE TUBING HAD BEEN SECURED TO THE CONDUIT SUPPORT BRACKET WITH ELECTRICAL TAPE, ALLOWING AC INDUCED CURRENT ON THE PIPELINE TO TRAVEL TO GROUND VIA A PIPE SUPPORT AROUND THE PIPELINE INSULATING GASKET. THIS RESULTED IN ELECTRICAL ARCHING FROM THE AC INDUCED CURRENT ON THE PIPELINE AND THE TUBING. THE ELECTRICAL ARCHING RESULTED IN A PINHOLE IN THE TUBING AND SERVED AS THE IGNITION SOURCE FOR THE FLAME.

About This Pipeline Incident

Pipeline incident data is reported to the Pipeline and Hazardous Materials Safety Administration (PHMSA). All significant incidents involving fatalities, injuries, or property damage over $50,000 must be reported.

Back to All Incidents More Incidents in