PLANTATION PIPE LINE CO

hazardous_liquid Incident — — December 11, 2014

Incident Information

Incident DateDecember 11, 2014
OperatorPLANTATION PIPE LINE CO
CommodityREFINED AND/OR PETROLEUM PRODUCT (NON-HVL) WHICH IS A LIQUID
Pipeline Typehazardous_liquid

Location

State
Coordinates34.54502, -82.50691

Cause

CauseINCORRECT OPERATION
SubcauseOTHER INCORRECT OPERATION

Casualties

Fatalities0
Injuries0

Costs

Property Damage$0
Emergency Response$0
Other Costs$0

Location Map

Incident Narrative

A FLASH FIRE OCCURRED DURING CUT OUT OF A SECTION OF PIPE ON THE 26-INCH CNG PIPELINE THAT INCLUDED A THREAD-O-RING (TOR). THE FLASH FIRE LOCATION WAS APPROXIMATELY 300 FEET DOWNSTREAM OF A LEAK REPAIR SITE. WELDING AT THE LEAK REPAIR SITE WAS NEAR COMPLETION WHEN THE FLASH FIRE OCCURRED AT THE TOR CUT OUT SITE. THE ON SCENE FIRE WATCH EXTINGUISHED THE FLASH FIRE. AN INVESTIGATION OF THE INCIDENT DETERMINED VACUUM ACTIVITIES AT THE TOR CUTOUT SITE TO ENSURE THE PIPING WAS FREE OF GASOLINE, CAUSED THE VAPOR ISOLATION SPHERE AND THE MUD PACK AT THE LEAK REPAIR SITE TO DISLODGE, ALLOWING VAPORS AND AIR TO TRAVEL INTO THE REPLACEMENT PIPE AT THE LEAK SITE CREATING A COMBUSTIBLE MIXTURE. SINCE WELDING WAS CONTINUING, THE SOURCE OF THE IGNITION WAS THE HEAT COMING FROM THE WELDING ACTIVITY CAUSING AN AUTO IGNITION OF THE VAPORS, WHICH THEN TRAVELED DOWN THE PIPE TO THE TOR SITE.

About This Pipeline Incident

Pipeline incident data is reported to the Pipeline and Hazardous Materials Safety Administration (PHMSA). All significant incidents involving fatalities, injuries, or property damage over $50,000 must be reported.

Back to All Incidents More Incidents in