COLONIAL PIPELINE CO
hazardous_liquid Incident —
Incident Information
| Report Date | — |
| Operator | COLONIAL PIPELINE CO |
| Commodity | — |
| Pipeline Type | hazardous_liquid |
Location
| State | |
| Coordinates | 39.84901, -75.50259 |
Cause
| Cause | EQUIPMENT FAILURE |
| Subcause | — |
Casualties
| Fatalities | 0 |
| Injuries | 0 |
Costs
| Property Damage | — |
| Lost Commodity | — |
| Public/Private Damage | — |
| Emergency Response | — |
| Environmental Remediation | — |
| Other Costs | — |
Location Map
Incident Narrative
ON 01/20/2015 AT 10:15 A.M. THE SENIOR OPERATOR PERFORMING A ROUTINE STATION CHECK DISCOVERED STAINED GRAVEL AROUND UNIT 4 CHECK VALVE. THE SENIOR OPERATOR NOTIFIED THE OPERATIONS MANAGER AND ENVIRONMENTAL SPECIALIST. UPON FURTHER INVESTIGATION, IT WAS DETERMINED THAT A CONTRACT CREW NEEDED TO EXCAVATE SOIL AROUND THE CHECK VALVE. THE CREW FOUND A FITTING THAT ATTACHES THE TUBING FROM THE CHECK VALVE UPPER SHAFT SPRING COVER TO THE LEAK DETECTION SYSTEM WAS CRACKED. REPAIRS WERE MADE AND CONTAMINATED SOIL WAS PLACED ON AN IMPERVIOUS ENVELOPE FOR FUTURE TREATMENT AT AN APPROVED OFF SITE FACILITY.