KINDER MORGAN WINK PIPELINE LP

hazardous_liquid Incident — — June 5, 2015

Incident Information

Incident DateJune 5, 2015
OperatorKINDER MORGAN WINK PIPELINE LP
CommodityCRUDE OIL
Pipeline Typehazardous_liquid

Location

State
Coordinates31.85260, -104.55730

Cause

CauseEQUIPMENT FAILURE
SubcausePUMP OR PUMP-RELATED EQUIPMENT

Casualties

Fatalities0
Injuries0

Costs

Property Damage$10,000
Emergency Response$1,000
Other Costs$0

Location Map

Incident Narrative

ON JUNE 5, 2015, THE INBOARD SEAL FAILED ON PUMP P-200 AT GUADALUPE PUMP STATION. AS A RESULT, 1.5 BARRELS OF CRUDE OIL WERE RELEASED. THE CRUDE OIL WAS CONTAINED WITHIN THE PUMP BUILDING. THE BEARINGS AND SEALS ON THE PUMP WERE REPLACED.