"KINDER MORGAN LIQUID TERMINALS, LLC"

hazardous_liquid Incident — — November 11, 2016

Incident Information

Incident DateNovember 11, 2016
Operator"KINDER MORGAN LIQUID TERMINALS, LLC"
CommodityREFINED AND/OR PETROLEUM PRODUCT (NON-HVL) WHICH IS A LIQUID
Pipeline Typehazardous_liquid

Location

State
Coordinates29.72536, -95.20334

Cause

CauseEQUIPMENT FAILURE
SubcausePUMP OR PUMP-RELATED EQUIPMENT

Casualties

Fatalities0
Injuries0

Costs

Property Damage$40,000
Emergency Response$2,000
Other Costs$0

Location Map

Incident Narrative

"ON 11-11-16 A PUMP SEAL ON A STRIPPER PUMP FAILED RELEASING 7 BARRELS OF PRODUCT INTO CONTAINMENT. A FAILED CHECK VALVE ALLOWED THE PUMP TO ROTATE BACKWARDS, DAMAGING THE PUMP SHAFT AND IMPELLER OF THE PUMP WHICH CAUSED THE VITON SEAL TO FAIL. THE PRODUCT WAS RECOVERED, THE PIT WAS CLEARED AND THE PUMP WAS PULLED. THE PUMP WAS REBUILT AND THE CHECK VALVE WAS REPLACED. 9/28/2017 - THIS REPORT WAS OPENED IN ERROR. NO CHANGES WERE MADE - DANIELLE STEPHENS"

About This Pipeline Incident

Pipeline incident data is reported to the Pipeline and Hazardous Materials Safety Administration (PHMSA). All significant incidents involving fatalities, injuries, or property damage over $50,000 must be reported.

Back to All Incidents More Incidents in