ONEOK NGL PIPELINE, LLC

hazardous_liquid Incident —

Incident Information

Report Date
OperatorONEOK NGL PIPELINE, LLC
Commodity—
Pipeline Typehazardous_liquid

Location

State
Coordinates32.43048, -100.05672

Cause

CauseCORROSION FAILURE
Subcause—

Casualties

Fatalities0
Injuries0

Costs

Property Damage
Lost Commodity
Public/Private Damage
Emergency Response
Environmental Remediation
Other Costs

Location Map

Incident Narrative

ON SEPTEMBER 24TH, 2015 ONEOK FIELD PERSONNEL AND CONTRACTORS BEGAN EXCAVATION TO LOCATE AND EVALUATE AN ANOMALY IDENTIFIED BY A RECENT INTERNAL INSPECTION TOOL RUN. AS THE CREW BEGAN THE EXCAVATION AN ODOR OF HYDROCARBONS WAS DETECTED BUT NO LEL'S WERE DETECTED BY PERSONAL GAS DETECTORS. AT THAT TIME, APPROXIMATELY 11:09 AM, ONEOK DECIDED TO SHUT THE LINE DOWN AND ISOLATE THE SEGMENT OF PIPE BEING EXCAVATED. AFTER EXCAVATING APPROXIMATELY 20 FT. OF PIPE, AT APPROXIMATELY 12:45 PM, WORKERS IDENTIFIED VAPOR LEAKING FROM A CORROSION POINT ON THE PIPE AND IMMEDIATELY INSTALLED A TEMPORARY CLAMP TO SEAL THE LEAK. THE ISOLATED SEGMENT WAS THEN PURGED OF HYDROCARBONS WITH NITROGEN. THE PIPE SECTION CONTAINING THE LEAK WAS REMOVED AND REPLACED WITH NEW PRETESTED PIPE. AFTER REPAIRS WERE MADE THE PIPELINE WAS RETURNED TO SERVICE AT 10:00 AM ON 9/27/2015.

About This Pipeline Incident

Pipeline incident data is reported to the Pipeline and Hazardous Materials Safety Administration (PHMSA). All significant incidents involving fatalities, injuries, or property damage over $50,000 must be reported.

Back to All Incidents More Incidents in