"KINDER MORGAN LIQUID TERMINALS, LLC"

hazardous_liquid Incident — — March 17, 2017

Incident Information

Incident DateMarch 17, 2017
Operator"KINDER MORGAN LIQUID TERMINALS, LLC"
CommodityREFINED AND/OR PETROLEUM PRODUCT (NON-HVL) WHICH IS A LIQUID
Pipeline Typehazardous_liquid

Location

State
Coordinates29.72783, -95.19976

Cause

CauseEQUIPMENT FAILURE
SubcausePUMP OR PUMP-RELATED EQUIPMENT

Casualties

Fatalities0
Injuries0

Costs

Property Damage$698,265
Emergency Response$0
Other Costs$0

Location Map

Incident Narrative

"A WELL LOCATED IN THE COLONIAL MANIFOLD AREA HAD GAS COLLECTING AT THE BOTTOM OF IT. A SEARCH FOR THE SOURCE INCLUDED ISOLATING A COLONIAL GAS OUTBOUND PUMP. THE PUMP WAS N2 TESTED AND FAILED THE TEST AND WAS IMMEDIATELY SHUT DOWN. THE PUMP WAS CLEARED AND ENTRY WAS MADE TO FIND THE SOURCE OF THE LEAK. A CRACK IN THE PUMP CAN WAS DISCOVERED AND REPAIRED NEAR THE SUCTION OF THE PUMP CAN. SETTLEMENT CAUSED THE CRACK AND THE PUMP CAN WAS HYDRO TESTED TO ENSURE ITS INTEGRITY, WHICH IT PASSED. CHRONOLOGY 3-17-2017: PRODUCT DISCOVERED AFTER HEAVY RAIN EVENT, BEGINNING OF EXPLORATORY PHASE 5-12-2017: IDENTIFIED PRODUCT TO BE FROM DOT ASSET 5-25-2017: PUMP CAN IDENTIFIED AS LOCATION OF RELEASE. 5-30-2017: CRACK ON PUMP CAN REMEDIATED 6-12-2017: PUMP BACK IN SERVICE."