PHILLIPS 66 PIPELINE LLC

hazardous_liquid Incident —

Incident Information

Report Date
OperatorPHILLIPS 66 PIPELINE LLC
Commodity—
Pipeline Typehazardous_liquid

Location

State
Coordinates29.99127, -93.98717

Cause

CauseCORROSION FAILURE
Subcause—

Casualties

Fatalities0
Injuries0

Costs

Property Damage
Lost Commodity
Public/Private Damage
Emergency Response
Environmental Remediation
Other Costs

Location Map

Incident Narrative

DURING OPERATOR ROUNDS, CRUDE OIL WAS DISCOVERED INSIDE THE CONCRETE CONTAINMENT AREA OF P100A/B BOOSTER PUMPS WHILE DELIVERING TO THE SPR LINE. PUMPS WERE IMMEDIATELY SHUT DOWN AND VALVES BLOCKED IN. NOTIFICATIONS WERE MADE TO SUPERVISORS AND CONTRACT CREW WAS CALLED OUT TO BEGIN CLEANUP. AFTER FURTHER INVESTIGATION IT WAS DETERMINED THAT THE UNDERGROUND PIPE, CROSSOVER PIPE BETWEEN THE DISCHARGE OF P100A AND THE SUCTION OF P100B USED TO RUN PUMP IN SERIES WAS LEAKING. MAINTENANCE CREWS ISOLATED AND BLIND FLANGED THE SHORT SECTION OF PIPE TO RETURN THE SYSTEM TO OPERATION THE FOLLOWING DAY. THE CROSSOVER PIPE USED TO RUN THE TWO PUMPS IN SERIES WAS NOT BEING UTILIZED DURING PUMPING OPERATION; THE PUMPS WERE BEING RUN IN PARALLEL AS IS TYPICAL FOR OPERATION OF BOTH BOOSTER PUMPS. IT WAS DETERMINED THAT THE SECTION OF PIPE WILL BE CLEANED, FILLED WITH CONCRETE/GROUT AND ABANDONED DUE TO ITS INFREQUENT USE. SCADA SYSTEM IS IN PLACE AND USED ON THE PIPELINE, THE LEAK OCCURRED UPSTREAM OF THE METERS. UPDATED RESPONSE COST AND SPILL VOLUMES ADDED TO REPORT.

About This Pipeline Incident

Pipeline incident data is reported to the Pipeline and Hazardous Materials Safety Administration (PHMSA). All significant incidents involving fatalities, injuries, or property damage over $50,000 must be reported.

Back to All Incidents More Incidents in