ENTERPRISE PRODUCTS OPERATING LLC

hazardous_liquid Incident —

Incident Information

Report Date
OperatorENTERPRISE PRODUCTS OPERATING LLC
Commodity—
Pipeline Typehazardous_liquid

Location

State
Coordinates30.01078, -94.05808

Cause

CauseEQUIPMENT FAILURE
Subcause—

Casualties

Fatalities0
Injuries0

Costs

Property Damage
Lost Commodity
Public/Private Damage
Emergency Response
Environmental Remediation
Other Costs

Location Map

Incident Narrative

TERMINAL OPERATOR IDENTIFIED DIESEL ON THE GROUND NEAR THE P1 PIPELINE BLOCK VALVES IN THE BEAUMONT TERMINAL. PRODUCT WAS FLOWING THROUGH THE LINE AT THE TIME OF LEAK IDENTIFICATION. PRESSURE ON THE PIPELINE DID NOT EXCEED MOP. FACILITY SUPERVISION CONTACTED QUALIFIED CONTRACTORS TO DETERMINE LEAK SOURCE AND MAKE NECESSARY REPAIRS. LEAK WAS DETERMINED TO BE ON TERMINAL SIDE OF A FLANGED MAINLINE VALVE CONNECTION. UPON FURTHER INSPECTION, BOLTS WERE DETERMINED TO BE UNEVENLY TORQUED DUE TO SOIL COMPACTION AND NEARBY HEAVY EQUIPMENT TRAFFIC. ALL FLANGE BOLTS WERE RE-TORQUED TO ENTERPRISE SPECIFICATIONS TO STOP THE LEAK. IMPACTED SOIL WAS REMOVED BY QUALIFIED CONTRACTORS. OPERATIONS THROUGH THE IMPACTED FLANGE WERE RESUMED AND NO FURTHER LEAKS WERE DETECTED.

About This Pipeline Incident

Pipeline incident data is reported to the Pipeline and Hazardous Materials Safety Administration (PHMSA). All significant incidents involving fatalities, injuries, or property damage over $50,000 must be reported.

Back to All Incidents More Incidents in