KINDER MORGAN CO2 CO. LP

hazardous_liquid Incident — — February 22, 2016

Incident Information

Incident DateFebruary 22, 2016
OperatorKINDER MORGAN CO2 CO. LP
CommodityCO2 (CARBON DIOXIDE)
Pipeline Typehazardous_liquid

Location

State
Coordinates37.47100, -108.79120

Cause

CauseEQUIPMENT FAILURE
SubcauseNON-THREADED CONNECTION FAILURE

Casualties

Fatalities0
Injuries0

Costs

Property Damage$130
Emergency Response$0
Other Costs$0

Location Map

Incident Narrative

ON 2/22/2016, A CONTRACTOR NOTIFIED KINDER MORGAN LOCAL OPERATIONS PERSONNEL THAT THERE WAS A LEAK AT THE YELLOW JACKET STATION. OPERATIONS PERSONNEL SECURED THE STATION, AND DETERMINED THAT THE LEAK WAS ON THE PIG LAUNCHER. THE LAUNCHER WAS ISOLATED AND BLOWN DOWN. THE O-RING ON THE LAUNCHER DOOR HAD FAILED. THE O-RING WAS REPLACED. IN ADDITION, THE O-RING AT THE RECEIVER WAS REPLACED.

About This Pipeline Incident

Pipeline incident data is reported to the Pipeline and Hazardous Materials Safety Administration (PHMSA). All significant incidents involving fatalities, injuries, or property damage over $50,000 must be reported.

Back to All Incidents More Incidents in