ONEOK NGL PIPELINE, LLC

hazardous_liquid Incident —

Incident Information

Report Date
OperatorONEOK NGL PIPELINE, LLC
Commodity—
Pipeline Typehazardous_liquid

Location

State
Coordinates30.31443, -95.01620

Cause

CauseEQUIPMENT FAILURE
Subcause—

Casualties

Fatalities0
Injuries0

Costs

Property Damage
Lost Commodity
Public/Private Damage
Emergency Response
Environmental Remediation
Other Costs

Location Map

Incident Narrative

ONEOK PIPELINE CONTROLS CENTER RECEIVED A CALL FROM LOCAL EMERGENCY RESPONSE TEAM AT 19:48, WHICH HAD RESPONDED TO A 911 CALL FROM THE PUBLIC REGARDING VAPORS COMING FROM A PIPELINE VALVE. PIPELINE CONTROL CENTER SHUTDOWN PIPELINE AND CONTACTED ONEOK PIPELINE SUPERVISOR AND LOCAL FIELD REPRESENTATIVE. LOCAL REPRESENTATIVE ARRIVED ONSITE AT 20:54 AND IDENTIFIED VAPORS COMING FROM THE VALVE STEM PACKING. VALVE STEM WAS PACKED WITH NEW PACKING AND RELEASE STOPPED AT 21:46. ONEOK PIPELINE CONTROL CENTER RESTARTED PIPELINE AND ONEOK REPRESENTATIVE REMAINED ONSITE UNTIL LINE WAS BACK TO FULL OPERATION PRESSURE TO INSURE PACKING HAD STOPPED THE RELEASE.