ENTERPRISE PRODUCTS OPERATING LLC
hazardous_liquid Incident —
Incident Information
| Report Date | — |
| Operator | ENTERPRISE PRODUCTS OPERATING LLC |
| Commodity | — |
| Pipeline Type | hazardous_liquid |
Location
| State | |
| Coordinates | 30.59266, -96.10051 |
Cause
| Cause | EQUIPMENT FAILURE |
| Subcause | — |
Casualties
| Fatalities | 0 |
| Injuries | 0 |
Costs
| Property Damage | — |
| Lost Commodity | — |
| Public/Private Damage | — |
| Emergency Response | — |
| Environmental Remediation | — |
| Other Costs | — |
Location Map
Incident Narrative
ON 7/29/2016 AT 23:17, A SEAL FAILURE ON A MAINLINE PUMP AT BRYAN STATION TRIGGERED THE SEAL FAIL AND HAZ GAS ALARMS IN THE CONTROL ROOM. THE SUCTION AND DISCHARGE VALVES ON THE UNIT WERE IMMEDIATELY CLOSED TO ISOLATE THE STATION. FIELD OPERATIONS BLEW DOWN THE SUCTION AND DISCHARGE PIPING IN THE EARLY MORNING OF 7/30 AND REPLACED THE SEAL ON 7/31. THE PUMP RESUMED NORMAL OPERATIONS ON 7/31 AT 16:30.
About This Pipeline Incident
Pipeline incident data is reported to the Pipeline and Hazardous Materials Safety Administration (PHMSA). All significant incidents involving fatalities, injuries, or property damage over $50,000 must be reported.