EQUISTAR CHEMICALS, L.P.

hazardous_liquid Incident — — August 9, 2016

Incident Information

Incident DateAugust 9, 2016
OperatorEQUISTAR CHEMICALS, L.P.
CommodityHVL OR OTHER FLAMMABLE OR TOXIC FLUID WHICH IS A GAS AT AMBI
Pipeline Typehazardous_liquid

Location

State
Coordinates29.70158, -95.04140

Cause

CauseEQUIPMENT FAILURE
SubcauseNON-THREADED CONNECTION FAILURE

Casualties

Fatalities0
Injuries0

Costs

Property Damage$1,500
Emergency Response$800
Other Costs$0

Location Map

Incident Narrative

AT APPROXIMATELY 6:40 P.M. ON AUGUST 9, 2016, A LEAK WAS DISCOVERED ON A PIPELINE PIG TRAP CLOSURE LOCATED AT A METER DELIVERY STATION FLOWING MATERIAL TO A CUSTOMER. AN IN-LINE INSPECTION TOOL WAS RUN THROUGH THE PIPELINE APPROXIMATELY 2.5 HOURS EARLIER TO MEET TEXAS RAILROAD COMMISSION PIPELINE SAFETY REGULATIONS. THE PIPELINE PIG TRAP CLOSURE O-RING WAS DETERMINED TO BE THE SOURCE OF THE LEAK AND THE FAILURE WAS ATTRIBUTED TO HIGH PRESSURE ETHYLENE INFILTRATION INTO THE O-RING MATERIAL, WHICH RESULTED IN DAMAGE TO THE O-RING WHEN THE TRAP WAS DEPRESSURED AND OPENED. THE O-RING REMAINED IN PLACE THROUGHOUT THREE TOOL RUNS AND THE VISIBLE PORTION OF THE O-RING WAS INSPECTED EACH TIME BEFORE THE TRAP WAS CLOSED. NO INDICATION OF MECHANICAL DAMAGE FROM REPEATED CLOSING OF THE TRAP WAS OBSERVED.