PHILLIPS 66 PIPELINE LLC

hazardous_liquid Incident —

Incident Information

Report Date
OperatorPHILLIPS 66 PIPELINE LLC
Commodity—
Pipeline Typehazardous_liquid

Location

State
Coordinates45.79437, -108.47915

Cause

CauseINCORRECT OPERATION
Subcause—

Casualties

Fatalities0
Injuries0

Costs

Property Damage
Lost Commodity
Public/Private Damage
Emergency Response
Environmental Remediation
Other Costs

Location Map

Incident Narrative

A TOR WAS DISCOVERED IN EARLY AUGUST WITH MISSING OUTSIDE THREADS DURING MAINTENANCE WORK. THE DECISION WAS MADE TO ABANDON THE TOR TO PREVENT FUTURE INCIDENTS. A NEW PLUG WAS INSERTED, THE CAP WAS INSTALLED AND STAMPED AS OUT OF SERVICE. DURING THE MORNING OF THE INCIDENT, THE MAINTENANCE TEAM DECIDED TO SEAL WELD THE ABANDONED CAP ON THE DAMAGED TOR. DURING WELDING, A SMALL AMOUNT OF PRODUCT (GASOLINE) BEGAN DRIPPING FROM UNDER THE CAP AND A SMALL FIRE IGNITED. NO PRODUCT REACHED THE GROUND. THE TEAM WAS ABLE TO QUICKLY PUT OUT THE FIRE WITH A FIRE EXTINGUISHER. UPDATE 5/18/2018 THE DRIPS STOPPED AFTER AFTER LINE WAS SHUT DOWN AND THE PRESSURE WAS REDUCED. IT WAS THEN DECIDED TO REMOVE THE ENTIRE SECTION OF PIPING WHERE THE TOR WAS LOCATED. OUR PROCEDURE HAS BEEN UPDATED IN MAY 2016 TO NOT ALLOW WELDING ON TOR FITTINGS WITH THE PLUG INSTALLED. THIS PROCEDURAL CHANGE WAS NOT KNOW BY THE MAINTENANCE GROUP DUE TO NOT IDENTIFYING THEM ON THE MOC FOR THE CHANGE ON THIS PROCEDURE. THE MOC DISTRIBUTION LIST WAS REVIEWED AND UPDATED. 5/28/2018 PER NOTIFICATION FROM BRIAN PIERZINA REPORT WAS NOT SUBMITTED AS A FINAL WHEN UPDATED. SUBMITTED AS FINAL

About This Pipeline Incident

Pipeline incident data is reported to the Pipeline and Hazardous Materials Safety Administration (PHMSA). All significant incidents involving fatalities, injuries, or property damage over $50,000 must be reported.

Back to All Incidents More Incidents in