ENTERPRISE PRODUCTS OPERATING LLC

hazardous_liquid Incident —

Incident Information

Report Date
OperatorENTERPRISE PRODUCTS OPERATING LLC
Commodity—
Pipeline Typehazardous_liquid

Location

State
Coordinates33.53872, -103.98749

Cause

CauseINCORRECT OPERATION
Subcause—

Casualties

Fatalities0
Injuries0

Costs

Property Damage
Lost Commodity
Public/Private Damage
Emergency Response
Environmental Remediation
Other Costs

Location Map

Incident Narrative

ON 08/23/2016 A CONTRACTOR CREW WAS INSTALLING PIG TRAP EQUIPMENT AND ASSOCIATED PIPING AT WHITE LAKES STATION. AT APPROXIMATELY 19:45 A POPPING SOUND WAS HEARD AND SMOKE WAS SEEN ESCAPING A TOR. THE FLASH FIRE WAS COMPLETELY CONTAINED WITHIN THE PIPE AND WAS NEVER VISIBLE. PRIOR TO THE FLASH FIRE OCCURRING, ZERO LELS WERE DETECTED INSIDE THE PIPE AT THE WORK SITE. 2/14/2017 UPON COMPLETION OF THE INVESTIGATION, IT WAS DETERMINED THAT VAPORS WERE PRESENT AT A LOW POINT DOWNSTREAM, RESIDUAL PRODUCT, OF WHERE THE HOT WORK WAS BEING PERFORMED. SPARKS FROM THE HOT WORK TRAVELED TO THE DOWNSTREAM LOW POINT AND IGNITED THE RESIDUAL VAPORS. 7/3/2018 INCIDENT INVESTIGATION INDICATED THAT CONTRACTOR FAILED TO ADEQUATELY FOLLOW SAFETY POLICY. CONSTRUCTION TASKS WERE NOT DOT COVERED TASKS THEREFORE NO DOT DRUG TESTING WAS REQUIRED.