CHAPARRAL ENERGY, LLC

hazardous_liquid Incident —

Incident Information

Report Date
OperatorCHAPARRAL ENERGY, LLC
Commodity—
Pipeline Typehazardous_liquid

Location

State
Coordinates36.20292, -100.92051

Cause

CauseOTHER OUTSIDE FORCE DAMAGE
Subcause—

Casualties

Fatalities0
Injuries0

Costs

Property Damage
Lost Commodity
Public/Private Damage
Emergency Response
Environmental Remediation
Other Costs

Location Map

Incident Narrative

ON 9/22/2016, AN OPERATOR OF AN AGRICULTURE FIELD SPRAYING RIG REPORTED TO US THAT HIS SPRAY BOOM STRUCK AN ABOVE-GROUND BLOWDOWN RISER, AT A MAIN LINE VALVE LOCATION, AND CAUSED CO2 TO BE RELEASED INTO THE ATMOSPHERE. THE SPRAY RIG OPERATOR WAS INSTRUCTED TO LEAVE THE IMMEDIATE AREA AND MOVE TO A DESIGNATED AREA TO WAIT FOR CHAPARRAL MIDSTREAM PERSONNEL TO ARRIVE. CHAPARRAL MIDSTREAM PERSONNEL ARRIVED AT THE AFFECTED VALVE SITE LOCATION, CONFIRMED THE EXISTENCE OF A CO2 LEAK IMMEDIATELY DOWNSTREAM OF MLV 1 , AND SECURED THE AREA. THE RELEASE DID NOT RESULT IN EXPLOSION, FIRE, DEATH, PERSONAL INJURY, SIGNIFICANT PROPERTY DAMAGE, OR POLLUTION OF ANY WATER BODY, AND WAS CONFINED TO CHAPARRAL PROPERTY AT THE VALVE LOCATION. THE DAMAGED BLOWDOWN RISER WAS ISOLATED BY CLOSING THE UPSTREAM AND DOWNSTREAM VALVES, AND THAT ISOLATED SEGMENT WAS THEN BLOWN DOWN USING THE BLOWDOWN RISER AT MLV 2. THE DAMAGED BLOWDOWN RISER WAS REPAIRED BY REPLACING THE FLANGE AND CONNECTION. X-RAY OF ALL WELDS ON THE REPLACEMENT JOINT WAS ACCEPTED. LATER THAT SAME DAY, THE AIR IN THE AFFECTED SEGMENT WAS PURGED WITH CO2, AND WAS RETURNED TO SERVICE IN A SAFE MANNER WITHOUT INCIDENT.

About This Pipeline Incident

Pipeline incident data is reported to the Pipeline and Hazardous Materials Safety Administration (PHMSA). All significant incidents involving fatalities, injuries, or property damage over $50,000 must be reported.

Back to All Incidents More Incidents in